{"id":2747,"date":"2024-02-01T10:56:57","date_gmt":"2024-02-01T09:56:57","guid":{"rendered":"https:\/\/schupp.ch\/p\/temperature-limiter-type-cr6-sr6\/"},"modified":"2025-11-28T15:52:22","modified_gmt":"2025-11-28T14:52:22","slug":"temperature-limiter-type-cr6-sr6","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/temperature-limiter-type-cr6-sr6\/","title":{"rendered":"Thermal Protectors Type CR6 \/ SR6; 4.0 &#8211; 25A"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td width=\"302\">\n<h5 style=\"text-align: center;\">CR6<\/h5>\n<\/td>\n<td width=\"302\">\n<h5 style=\"text-align: center;\">SR6<\/h5>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-4140\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CR6-264x300.jpg\" alt=\"\" width=\"264\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CR6-264x300.jpg 264w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CR6.jpg 283w\" sizes=\"auto, (max-width: 264px) 100vw, 264px\" \/><\/td>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-4143\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SR6-214x300.jpg\" alt=\"\" width=\"214\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SR6-214x300.jpg 214w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SR6.jpg 232w\" sizes=\"auto, (max-width: 214px) 100vw, 214px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"633\">\n<tbody>\n<tr>\n<td width=\"361\">Switch type:<\/td>\n<td width=\"137\"><strong>NC contact CR6 self-retaining<\/strong><\/td>\n<td width=\"134\"><strong>NC contact SR6 latching<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">isolated:<\/td>\n<td width=\"137\">no<\/td>\n<td width=\"134\">yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Temperature<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Nominal switching temperature (NST), in 5 K steps [\u00b0C]<\/td>\n<td colspan=\"2\" width=\"271\">60 &#8211; 180<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Tolerance range \u2264 140 \u00b0C Tol [ [K]<\/td>\n<td colspan=\"2\" width=\"271\">\u00b1 5<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Tolerance range \u2265140 \u00b0C Tol [ [K]<\/td>\n<td colspan=\"2\" width=\"271\">\u00b1 10<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Reverse Switch Temperature (RST below NST) UL [ [K]<\/td>\n<td colspan=\"2\" width=\"271\">\u2265 35<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">(defined RST on customer request) VDE [ \u00b0C]<\/td>\n<td colspan=\"2\" width=\"271\">\u2265 35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Tension<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Operating voltage range up to &#8230;<\/td>\n<td colspan=\"2\" width=\"271\">250 V<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Rated voltage AC [VAC]<\/td>\n<td colspan=\"2\" width=\"271\">120\/230 (VDE), 250 (UL)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Current\/switching cycles<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Rated current &#8211; cos \u03c6 = 1.0 [A] \/ [n]<\/td>\n<td colspan=\"2\" width=\"271\"><strong>10,0 <\/strong>\/ 1&#8217;000<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Rated current -cos \u03c6 = 0.6 [A] \/ [n]<\/td>\n<td colspan=\"2\" width=\"271\"><strong>6,3 <\/strong>\/ 1&#8217;000<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">max. Switching current cos \u03c6 = 1.0 [A] \/ [n]<\/td>\n<td colspan=\"2\" width=\"271\"><strong>25,0 <\/strong>\/ 1&#8217;000<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Additional specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">High-voltage strength [kV]<\/td>\n<td width=\"137\">&#8212;<\/td>\n<td width=\"134\">2<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Total bounce time [ms]<\/td>\n<td colspan=\"2\" width=\"271\">&lt; 1<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Contact resistance (according to MIL-STD R5757) [m\u03a9]<\/td>\n<td colspan=\"2\" width=\"271\"><u>&lt;<\/u> 50<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Vibration resistance 10 &#8230; 60 Hz [<sup>m\/s2<\/sup>]<\/td>\n<td colspan=\"2\" width=\"271\">100<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Compressive strength of the switch housing [N]<\/td>\n<td colspan=\"2\" width=\"271\">600<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Available Licenses and Approvals<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">please specify<\/td>\n<td colspan=\"2\" width=\"271\">IEC, ENEC, VDE, UL, CSA, CQC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Dimensions (standard)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Diameter \u00d8 d [mm]<\/td>\n<td width=\"137\">9,0<\/td>\n<td width=\"134\">9,4<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Overall height h [mm]<\/td>\n<td width=\"137\">from 6.3<\/td>\n<td width=\"134\">from 6.7<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Length of insulation cap l [mm]<\/td>\n<td width=\"137\">&#8212;<\/td>\n<td width=\"134\">17,0<\/td>\n<\/tr>\n<tr>\n<td width=\"361\">Standard stranded wire connection:<\/td>\n<td colspan=\"2\" width=\"271\">0.75 mm2\/AWG 18<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Functional diagram<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\">&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-4146\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CR6_FSB.jpg\" alt=\"\" width=\"368\" height=\"235\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The ceramic resistor connected in parallel to the switch heats up after the contact opens, which keeps the contact in the open state.<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"302\"><strong>CR6<\/strong><\/td>\n<td width=\"302\"><strong>SR6<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-8635\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-300x300.jpg 300w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-600x600.jpg 600w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-900x900.jpg 900w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-100x100.jpg 100w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-150x150.jpg 150w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-768x768.jpg 768w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CR6-1024x1024.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-8639\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-300x300.jpg 300w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-600x600.jpg 600w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-900x900.jpg 900w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-100x100.jpg 100w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-150x150.jpg 150w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-768x768.jpg 768w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SR6-1024x1024.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Note<\/strong><\/p>\n<p>The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<h5><strong>The types CR6 <\/strong>and <strong>SR6 are <\/strong>not automatically resetting, voltage-retained<strong>, <\/strong>with connection cables, with Expoxy<\/h5>\n<h5><\/h5>\n<h5><strong>SR6 <\/strong>with Mylar\u00ae-Nomex\u00ae insulating cap<\/h5>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":2306,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[187,292],"product_tag":[],"class_list":{"0":"post-2747","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-temperature-monitoring","7":"product_cat-temperature-limiter-4-0-25-a","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/2747","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/2306"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=2747"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=2747"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=2747"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=2747"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}