{"id":2757,"date":"2024-02-01T10:24:52","date_gmt":"2024-02-01T09:24:52","guid":{"rendered":"https:\/\/schupp.ch\/p\/temperature-limiter-type-cz1-sz1\/"},"modified":"2025-11-28T16:00:42","modified_gmt":"2025-11-28T15:00:42","slug":"temperature-limiter-type-cz1-sz1","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/temperature-limiter-type-cz1-sz1\/","title":{"rendered":"Thermal Protectors type CZ1 \/ SZ1; 1.6 &#8211; 7.5 A"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td width=\"302\">\n<h5 style=\"text-align: center;\">CZ1<\/h5>\n<\/td>\n<td width=\"302\">\n<h5 style=\"text-align: center;\">SZ1<\/h5>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-4071 aligncenter\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CZ01-237x300.jpg\" alt=\"\" width=\"237\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CZ01-237x300.jpg 237w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/CZ01.jpg 266w\" sizes=\"auto, (max-width: 237px) 100vw, 237px\" \/><\/td>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-4074 aligncenter\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SZ01-221x300.jpg\" alt=\"\" width=\"221\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SZ01-221x300.jpg 221w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SZ01.jpg 247w\" sizes=\"auto, (max-width: 221px) 100vw, 221px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"276\"><strong>Switching type<\/strong><\/td>\n<td width=\"179\"><strong>NC contact CZ1<\/strong><\/td>\n<td width=\"179\"><strong>NC contact SZ1<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\"><\/td>\n<td colspan=\"2\" width=\"357\"><strong>Resetting, defined current sensitive<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Insulated: Insulation cap<\/td>\n<td width=\"179\">No<\/td>\n<td width=\"179\">Yes<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Temperature<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Nominal switching temperature (NST) in 5 K steps \u00b0C<\/td>\n<td colspan=\"2\" width=\"357\">70 &#8211; 160<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Tolerance range NST <u>&lt; 140 \u00b0C Tol (K)<\/u><\/td>\n<td colspan=\"2\" width=\"357\"><u>+<\/u> <u>5<\/u><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Reverse Switch Temperature (RST below NST)\u00a0 \u00a0UL<br \/>\n(defined RST possible on request)\u00a0 \u00a0 VDE<\/td>\n<td colspan=\"2\" width=\"357\">&#8211; 35 <u>+<\/u> 15<u><br \/>\n\u2265 <\/u>35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Tension<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">max. operating voltage range up to &#8230;<\/td>\n<td colspan=\"2\" width=\"357\">500 VAC \/ 14 V DC<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Operating voltage AC<\/td>\n<td colspan=\"2\" width=\"357\">250 (VDE), 277 (UL)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Current \/ switching cycles<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Rated current &#8211; cos \u03c6 = 1.0 [A] \/ [n]<\/td>\n<td colspan=\"2\" rowspan=\"3\" width=\"357\">2.0 \/ 3,000<br \/>\n1.6 \/ 3,000<br \/>\n4.0 \/ 3,000<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Rated current &#8211; cos \u03c6 = 0.6 [A] \/ [n]<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Max. Switching current [A] \/ [n]<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Rated voltage DC<\/td>\n<td colspan=\"2\" width=\"357\">12<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Max. Switching current DC [A] \/ [n]<\/td>\n<td colspan=\"2\" width=\"357\">on request<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Additional specifications<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Series resistors for setting the current sensitivity<\/td>\n<td colspan=\"2\" width=\"357\">From 0.12 \u03a9 to 70 \u03a9<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">High-voltage strength (kV)<\/td>\n<td width=\"179\">2<\/td>\n<td width=\"179\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Total bounce time (ms)<\/td>\n<td colspan=\"2\" width=\"357\">&lt; 1<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Contact resistance (according to MIL-STD R5757) (m\u03a9)<\/td>\n<td colspan=\"2\" width=\"357\"><u>&lt; <\/u>50<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Vibration resistance 10 &#8230; 60 Hz (m\/s2)<\/td>\n<td colspan=\"2\" width=\"357\">100<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Compressive strength of the switch housing (N)<\/td>\n<td colspan=\"2\" width=\"357\">450<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Suitable for installation in protection class<\/td>\n<td width=\"179\">I + II<\/td>\n<td width=\"179\">I<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Impregnation resistance<\/td>\n<td colspan=\"2\" width=\"357\">suitable<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Available Licenses and Approvals<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">please specify<\/td>\n<td colspan=\"2\" width=\"357\">IEC, ENEC, VDE, UL, CSA, COC<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Dimensions (standard)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Diameter \u00d8 d (mm)<\/td>\n<td width=\"179\">10,0<\/td>\n<td width=\"179\">10,0<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Overall height h (mm)<\/td>\n<td width=\"179\">from 7.0<\/td>\n<td width=\"179\">from 3.4<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Length of the connection pins (mm)<\/td>\n<td width=\"179\">&#8212;<\/td>\n<td width=\"179\">14,0 \/ 20,0<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Thread (size x length) (M x mm)<\/td>\n<td width=\"179\">M4 x 5.0<\/td>\n<td width=\"179\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Width across flats \/ max. Torque (mm \/ Nm)<\/td>\n<td width=\"179\">10,0 \/ 2<\/td>\n<td width=\"179\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td width=\"276\">Standard connection<\/td>\n<td width=\"179\">Stranded wire 0.25 mm2 \/ AWG22<\/td>\n<td width=\"179\">Connection wire d = 0.5 mm<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\"><strong>Function &#8211; Circuit diagram<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"633\">&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3845 aligncenter\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/SB_03.jpg\" alt=\"\" width=\"288\" height=\"174\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The series resistor is used to adjust the current sensitivity, as its heating causes the switch to trip earlier.<\/p>\n<p>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"302\">\n<h5><strong>CZ1<\/strong><\/h5>\n<\/td>\n<td width=\"302\">\n<h5><strong>SZ1<\/strong><\/h5>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-8541\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-300x300.jpg 300w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-600x600.jpg 600w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-900x900.jpg 900w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-100x100.jpg 100w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-150x150.jpg 150w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-768x768.jpg 768w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_CZ1-1024x1024.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<td width=\"302\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-8544\" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-300x300.jpg 300w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-600x600.jpg 600w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-900x900.jpg 900w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-100x100.jpg 100w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-150x150.jpg 150w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-768x768.jpg 768w, https:\/\/schupp.ch\/wp-content\/uploads\/2024\/02\/TW_SZ1-1024x1024.jpg 1024w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Note<\/strong><\/p>\n<p>The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<h5><strong>Thy types CZ1, SZ1<\/strong> are current-sensitive switches, automatically resetting, with connecting cables, with or without epoxy<\/h5>\n<h5><\/h5>\n<h5><strong>The type CZ1<\/strong> is not isolated<\/h5>\n<h5><\/h5>\n<h5><strong>The type SZ1<\/strong> is insulated with a Mylar\u00ae-Nomex\u00ae cap<\/h5>\n<h5><\/h5>\n<p>&nbsp;<\/p>\n<h5><\/h5>\n<h5><\/h5>\n<h5>Ideal for installation on windings of electric motors, transformers or ballasts<\/h5>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":2306,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[187,215],"product_tag":[],"class_list":{"0":"post-2757","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-temperature-monitoring","7":"product_cat-temperature-limiter-1-6-a-7-5-a","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/2757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/2306"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=2757"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=2757"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=2757"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=2757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}