{"id":5905,"date":"2024-01-25T16:38:35","date_gmt":"2024-01-25T15:38:35","guid":{"rendered":"https:\/\/schupp.ch\/p\/ptfe-glass-silk-switching-strand-tegl\/"},"modified":"2025-12-17T16:24:53","modified_gmt":"2025-12-17T15:24:53","slug":"ptfe-glass-silk-switching-strand-tegl","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/ptfe-glass-silk-switching-strand-tegl\/","title":{"rendered":"PTFE\/Fibre Glass Single Core Hook Up wires TEGL"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h5><strong>Construction of cable<\/strong><\/h5>\n<p>&nbsp;<\/p>\n<p><strong>Conductor:<\/strong><br \/>\nNickel-plated copper stranded wire or pure nickel<\/p>\n<p><strong>Insulation:<\/strong><br \/>\nPTFE 5Y according to VDE 0207 Part 6 Glass fibre braid with impregnation<\/p>\n<p><strong>Marking:<\/strong><br \/>\nOptionally with coloured marking thread<\/p>\n<p><strong>Temperature range:<\/strong><br \/>\n-50 \u00b0C to + 260 \u00b0C, briefly 300 \u00b0C<\/p>\n<p><strong>Nominal voltage:<\/strong><br \/>\n600 volts<\/p>\n<p><strong>Test voltage:<\/strong><br \/>\n3.4 kV<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensions<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"111\"><strong>Master number<\/strong><\/td>\n<td width=\"89\"><strong>Cross section [mm2]<\/strong><\/td>\n<td width=\"89\"><strong>Strand structure<\/strong><\/td>\n<td width=\"89\"><strong>max. strand \u00d8 [mm]<\/strong><\/td>\n<td width=\"89\"><strong>Outer \u00d8 [mm]<\/strong><\/td>\n<td width=\"81\"><strong>Cu number [kg\/km]<\/strong><\/td>\n<td width=\"84\"><strong>Weight approx [kg\/km]<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0050<\/strong><\/td>\n<td width=\"89\">0,5<\/td>\n<td width=\"89\">16 x 0,203<\/td>\n<td width=\"89\">1<\/td>\n<td width=\"89\">2<\/td>\n<td width=\"81\">4,8<\/td>\n<td width=\"84\">10<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0075<\/strong><\/td>\n<td width=\"89\">0,75<\/td>\n<td width=\"89\">24 x 0,203<\/td>\n<td width=\"89\">1,25<\/td>\n<td width=\"89\">2,2<\/td>\n<td width=\"81\">7,5<\/td>\n<td width=\"84\">14<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0100<\/strong><\/td>\n<td width=\"89\">1<\/td>\n<td width=\"89\">32 x 0,203<\/td>\n<td width=\"89\">1,4<\/td>\n<td width=\"89\">2,4<\/td>\n<td width=\"81\">9,8<\/td>\n<td width=\"84\">16<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0150<\/strong><\/td>\n<td width=\"89\">1,5<\/td>\n<td width=\"89\">30 x 0,254<\/td>\n<td width=\"89\">1,7<\/td>\n<td width=\"89\">2,7<\/td>\n<td width=\"81\">14,4<\/td>\n<td width=\"84\">22<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0250<\/strong><\/td>\n<td width=\"89\">2,5<\/td>\n<td width=\"89\">50 x 0,254<\/td>\n<td width=\"89\">2,15<\/td>\n<td width=\"89\">3,3<\/td>\n<td width=\"81\">24,4<\/td>\n<td width=\"84\">36<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0400<\/strong><\/td>\n<td width=\"89\">4<\/td>\n<td width=\"89\">56 x 0,3<\/td>\n<td width=\"89\">2,7<\/td>\n<td width=\"89\">3,8<\/td>\n<td width=\"81\">38<\/td>\n<td width=\"84\">52<\/td>\n<\/tr>\n<tr>\n<td width=\"111\"><strong>SLTEGL0600<\/strong><\/td>\n<td width=\"89\">6<\/td>\n<td width=\"89\">84 x 0,3<\/td>\n<td width=\"89\">3,3<\/td>\n<td width=\"89\">4,5<\/td>\n<td width=\"81\">58<\/td>\n<td width=\"84\">71<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Part number:<\/strong><\/p>\n<p>Conductor:<br \/>\nN = Cu nickel-plated<br \/>\nR = Pure nickel<\/p>\n<p>Example:<br \/>\nSLTEGL0050N<br \/>\nSLTEGL0050 = Master number<br \/>\nN = Cu Nickel Plated<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<h5>This cable can be used for wiring at high ambient temperatures and increased mechanical stress, e.g.<\/h5>\n<p>&nbsp;<\/p>\n<h5><\/h5>\n<ul>\n<li>\n<h5>Domestic appliances (stoves, hotplates, ovens)<\/h5>\n<\/li>\n<li>\n<h5>Extrusion and drying systems<\/h5>\n<\/li>\n<li>\n<h5>Electric heaters<\/h5>\n<\/li>\n<li>\n<h5>Aerospace<\/h5>\n<\/li>\n<li>\n<h5>Traffic engineering<\/h5>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h5><strong>Brief Information on Cable Insulations made of Fluoroplastics<\/strong><\/h5>\n<p><a href=\"https:\/\/schupp.ch\/en\/p\/brief-information-on-cable-insulation-made-of-fluoroplastics\/\">Details<\/a><\/p>\n","protected":false},"featured_media":1884,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[117,199],"product_tag":[],"class_list":{"0":"post-5905","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-electrical-cables","7":"product_cat-high-temperature-pipes","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/5905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/1884"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=5905"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=5905"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=5905"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=5905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}