{"id":5908,"date":"2024-01-25T16:42:20","date_gmt":"2024-01-25T15:42:20","guid":{"rendered":"https:\/\/schupp.ch\/p\/mica-ceramic-fiber-switching-strand-gliga\/"},"modified":"2025-12-17T15:09:37","modified_gmt":"2025-12-17T14:09:37","slug":"mica-ceramic-fiber-switching-strand-gliga","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/mica-ceramic-fiber-switching-strand-gliga\/","title":{"rendered":"Mica\/Ceramic fiber single core GLIGA"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h5><strong>Structure<\/strong><\/h5>\n<p>&nbsp;<\/p>\n<p><strong>Conductor:<\/strong><br \/>\nnickel-plated copper strand, pure nickel or special alloy<\/p>\n<p><strong>Insulation:<\/strong><br \/>\nmica-banded ceramic fiber braid with impregnation<\/p>\n<p><strong>Marking:\u00a0<\/strong><br \/>\noptionally with colored identification thread<\/p>\n<p><strong>Temperature range:<br \/>\n<\/strong>Cu nickel-plated &#8211; 50 \u00b0C to + 400 \u00b0C<br \/>\nPure nickel\u00a0 \u00a0 &#8211; 50 \u00b0C to + 700 \u00b0C\u00a7<br \/>\nNiCr8020\u00a0 \u00a0 &#8211; 50 \u00b0C to + 1250 \u00b0C<\/p>\n<p><strong>Nominal voltage:\u00a0<\/strong><br \/>\n300\/500 volts<\/p>\n<p><strong>Test voltage:<\/strong><br \/>\n2 kV<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Dimensions<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"108\"><strong>Master number<\/strong><\/td>\n<td width=\"89\"><strong>Cross section [mm2]<\/strong><\/td>\n<td width=\"89\"><strong>Strand structure<\/strong><\/td>\n<td width=\"89\"><strong>max. strand \u00d8 [mm]<\/strong><\/td>\n<td width=\"89\"><strong>Outer \u00d8 [mm]*<\/strong><\/td>\n<td width=\"83\"><strong>Cu number [kg\/km]<\/strong><\/td>\n<td width=\"86\"><strong>Weight approx [kg\/km]<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0050<\/strong><\/td>\n<td width=\"89\">0,5<\/td>\n<td width=\"89\">16 x 0,203<\/td>\n<td width=\"89\">1<\/td>\n<td width=\"89\">2,4<\/td>\n<td width=\"83\">4,8<\/td>\n<td width=\"86\">11<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0075<\/strong><\/td>\n<td width=\"89\">0,75<\/td>\n<td width=\"89\">24 x 0,203<\/td>\n<td width=\"89\">1,25<\/td>\n<td width=\"89\">2,5<\/td>\n<td width=\"83\">7,5<\/td>\n<td width=\"86\">18<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0100<\/strong><\/td>\n<td width=\"89\">1<\/td>\n<td width=\"89\">32 x 0,203<\/td>\n<td width=\"89\">1,4<\/td>\n<td width=\"89\">3,2<\/td>\n<td width=\"83\">9,8<\/td>\n<td width=\"86\">23<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0150<\/strong><\/td>\n<td width=\"89\">1,5<\/td>\n<td width=\"89\">30 x 0,254<\/td>\n<td width=\"89\">1,7<\/td>\n<td width=\"89\">3,6<\/td>\n<td width=\"83\">14,4<\/td>\n<td width=\"86\">28<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0250<\/strong><\/td>\n<td width=\"89\">2,5<\/td>\n<td width=\"89\">50 x 0,254<\/td>\n<td width=\"89\">2,15<\/td>\n<td width=\"89\">3,9<\/td>\n<td width=\"83\">24,4<\/td>\n<td width=\"86\">46<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0400<\/strong><\/td>\n<td width=\"89\">4<\/td>\n<td width=\"89\">56 x 0,30<\/td>\n<td width=\"89\">2,7<\/td>\n<td width=\"89\">5,2<\/td>\n<td width=\"83\">38<\/td>\n<td width=\"86\">70<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA0600<\/strong><\/td>\n<td width=\"89\">6<\/td>\n<td width=\"89\">84 x 0,30<\/td>\n<td width=\"89\">3,3<\/td>\n<td width=\"89\">6,0<\/td>\n<td width=\"83\">58<\/td>\n<td width=\"86\">104<\/td>\n<\/tr>\n<tr>\n<td width=\"108\"><strong>SLGLIGA1000<\/strong><\/td>\n<td width=\"89\">10<\/td>\n<td width=\"89\">80 x 0,4<\/td>\n<td width=\"89\">4,8<\/td>\n<td width=\"89\">7,4<\/td>\n<td width=\"83\">100<\/td>\n<td width=\"86\">147<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>* Diameter tolerance according to intended use<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Item number: <\/strong><\/p>\n<p>Main number conductor<br \/>\nConductor:<br \/>\nNPC = Cu nickel-plated<br \/>\nR = Pure nickel NiCr = NiCr8020<br \/>\nExample: SKGLHGLP20022NPC<br \/>\nSKGLHGLP20022 = Main number<br \/>\nNPC = Cu nickel-plated<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<h5>This cable can be used for wiring at high ambient temperatures and increased mechanical stress, e.g.<\/h5>\n<p>&nbsp;<\/p>\n<ul>\n<li>\n<h5>Glass and ceramic production<\/h5>\n<\/li>\n<li>\n<h5>Industrial ovens<\/h5>\n<\/li>\n<li>\n<h5>Electric heaters<\/h5>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":1896,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[117,199],"product_tag":[],"class_list":{"0":"post-5908","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-electrical-cables","7":"product_cat-high-temperature-pipes","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/5908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/1896"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=5908"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=5908"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=5908"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=5908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}