{"id":5990,"date":"2024-01-24T17:49:33","date_gmt":"2024-01-24T16:49:33","guid":{"rendered":"https:\/\/schupp.ch\/p\/peek-electrical-insulating-films\/"},"modified":"2026-02-17T17:34:01","modified_gmt":"2026-02-17T16:34:01","slug":"peek-electrical-insulating-films","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/peek-electrical-insulating-films\/","title":{"rendered":"PEEK electrical Films"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><strong>Application examples:<\/strong><\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"338\"><strong>Industry<\/strong><\/td>\n<td width=\"309\"><strong>Aerospace<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Electrical insulation<\/td>\n<td width=\"309\">Pressure sensors<\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Adhesive tapes<\/td>\n<td width=\"309\">Speaker cones and voice coils<\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Printed circuit board substrates<\/td>\n<td width=\"309\">Capacitors<\/td>\n<\/tr>\n<tr>\n<td width=\"338\">High-temperature labels<\/td>\n<td width=\"309\">Composite structures<\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Sealing washers in high-speed engines<\/td>\n<td width=\"309\">Suitable for use with lead-free solders<\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Sealing washers in cell phone hinges<\/td>\n<td width=\"309\"><\/td>\n<\/tr>\n<tr>\n<td width=\"338\">Flexible heating elements<\/td>\n<td width=\"309\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Standard thicknesses and widths:<\/strong><\/p>\n<p>The standard width of the film is 610 mm &#8211; widths up to 1500 mm on request. Standard thicknesses (in \u00b5m) &#8211; 12, 18, 25, 38, 50, 63, 75, 100, 125, 150, 200. Other thicknesses 250, 300, 500, 750 \u00b5m on request. The thickness tolerance is +\/- 7 %.<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"206\"><strong>Minimum purchase quantity 10 kg<\/strong><\/td>\n<td width=\"53\">25 \u00b5m<\/td>\n<td width=\"53\">50 \u00b5m<\/td>\n<td width=\"53\">75 \u00b5m<\/td>\n<td width=\"53\">100 \u00b5m<\/td>\n<td width=\"53\">150 \u00b5m<\/td>\n<td width=\"53\">200 \u00b5m<\/td>\n<td width=\"53\">300 \u00b5m<\/td>\n<td width=\"53\">500 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"206\">Surface area [m2]<\/td>\n<td width=\"53\">approx. 300<\/td>\n<td width=\"53\">approx. 160<\/td>\n<td width=\"53\">approx. 100<\/td>\n<td width=\"53\">approx. 80<\/td>\n<td width=\"53\">approx. 50<\/td>\n<td width=\"53\">approx. 40<\/td>\n<td width=\"53\">approx.26<\/td>\n<td width=\"53\">approx.15<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-9945 \" src=\"https:\/\/schupp.ch\/wp-content\/uploads\/2024\/01\/PEEK_Folien_01-EN.jpg\" alt=\"\" width=\"630\" height=\"408\" \/><\/p>\n<p><span data-contrast=\"auto\">Figure 1:\u00a0<\/span><span data-contrast=\"auto\">Physical properties at 23 \u00b0C and 200 \u00b0C for film, 50 \u00b5m (ISO 527)<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Mechanical properties with different film thicknesses:<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"446\">ISO 527 at 23 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"107\">25 \u00b5m<\/td>\n<td width=\"68\">50 \u00b5m<\/td>\n<td width=\"68\">125 \u00b5m<\/td>\n<td width=\"68\">250 \u00b5m<\/td>\n<td width=\"68\"><\/td>\n<td width=\"68\"><\/td>\n<\/tr>\n<tr>\n<td width=\"107\">Tensile strength<\/td>\n<td width=\"68\">MPa<\/td>\n<td width=\"68\">130<\/td>\n<td width=\"68\">120<\/td>\n<td width=\"68\">110<\/td>\n<td width=\"68\">100<\/td>\n<\/tr>\n<tr>\n<td width=\"107\">E-modulus<\/td>\n<td width=\"68\">GPa<\/td>\n<td width=\"68\">3.0<\/td>\n<td width=\"68\">2.8<\/td>\n<td width=\"68\">2.4<\/td>\n<td width=\"68\">2.2<\/td>\n<\/tr>\n<tr>\n<td width=\"107\">Tear elongation<\/td>\n<td width=\"68\">%<\/td>\n<td width=\"68\">&gt;150<\/td>\n<td width=\"68\">&gt;150<\/td>\n<td width=\"68\">&gt;150<\/td>\n<td width=\"68\">&gt;150<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Electrical properties with different film thicknesses:<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"6\" width=\"445\">ATSM D149, 23\u00b0C, 1\/4&#8243; electrode<\/td>\n<\/tr>\n<tr>\n<td width=\"159\"><\/td>\n<td width=\"58\"><\/td>\n<td width=\"56\">25 \u00b5m<\/td>\n<td width=\"50\">50 \u00b5m<\/td>\n<td width=\"58\">125 \u00b5m<\/td>\n<td width=\"64\">250 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Dielectric strength<\/td>\n<td width=\"58\">kV\/mm<\/td>\n<td width=\"56\">270<\/td>\n<td width=\"50\">190<\/td>\n<td width=\"58\">120<\/td>\n<td width=\"64\">70<\/td>\n<\/tr>\n<tr>\n<td width=\"159\">Breakdown voltage<\/td>\n<td width=\"58\">kV<\/td>\n<td width=\"56\">6.75<\/td>\n<td width=\"50\">9.5<\/td>\n<td width=\"58\">15<\/td>\n<td width=\"64\">17.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"243\"><strong>Test method<\/strong><\/td>\n<td width=\"126\">Test Condition<\/td>\n<td width=\"130\">Unit<\/td>\n<td width=\"65\">50 \u00b5m<\/td>\n<td width=\"65\"><\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Property<\/td>\n<td width=\"126\"><\/td>\n<td width=\"130\"><\/td>\n<td width=\"65\"><\/td>\n<td width=\"65\"><\/td>\n<\/tr>\n<tr>\n<td width=\"243\">E-modulus<\/td>\n<td width=\"126\">ISO 527<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">GPa<\/td>\n<td width=\"65\">2,8<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Tensile strength (at break)<\/td>\n<td width=\"126\">ISO 527<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">M Pa<\/td>\n<td width=\"65\">120<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Tear elongation<\/td>\n<td width=\"126\">ISO 527<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">%<\/td>\n<td width=\"65\">&gt;150<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Puncture resistance<\/td>\n<td width=\"126\">Def Stan 81-75<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">kJ\/m2<\/td>\n<td width=\"65\">26<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Tear strength<\/td>\n<td width=\"126\">ISO 6383-1<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">N\/m m<\/td>\n<td width=\"65\">6,7<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Shrinkage<\/td>\n<td width=\"126\">TM-VX-84<\/td>\n<td width=\"130\">200 \u00baC<\/td>\n<td width=\"65\">%<\/td>\n<td width=\"65\">&lt;2<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Density<\/td>\n<td width=\"126\">ISO 1183<\/td>\n<td width=\"130\">23 \u00baC<\/td>\n<td width=\"65\">kg\/dm3<\/td>\n<td width=\"65\">1,30<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Water absorption (50 % relative humidity)<\/td>\n<td width=\"126\">ISO 62<\/td>\n<td width=\"130\">23 \u00baC, 24h<\/td>\n<td width=\"65\">%<\/td>\n<td width=\"65\">0,04<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Linear coefficient of thermal expansion<\/td>\n<td width=\"126\">ASTM D696<\/td>\n<td width=\"130\">MD, below Tg<\/td>\n<td width=\"65\">ppm<\/td>\n<td width=\"65\">47<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Dielectric strength<\/td>\n<td width=\"126\">ASTM D149<\/td>\n<td width=\"130\">23 \u00baC, 1\/4&#8243; electrode<\/td>\n<td width=\"65\">kV\/mm<\/td>\n<td width=\"65\">190<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Contact resistance<\/td>\n<td width=\"126\">ASTM D257<\/td>\n<td width=\"130\">100 V, 23 \u00baC<\/td>\n<td width=\"65\">Ohm cm<\/td>\n<td width=\"65\">4 x 1016<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Dielectric constant<\/td>\n<td width=\"126\">ASTM D150<\/td>\n<td width=\"130\">23 \u00baC, 10 MHz<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"65\">3,5<\/td>\n<\/tr>\n<tr>\n<td width=\"243\">Loss factor tan \u03b4<\/td>\n<td width=\"126\">ASTM D150<\/td>\n<td width=\"130\">23 \u00baC, 10 MHz<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"65\">0,002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<h5>These films are non-reinforced and semi-crystalline from PEEK\u2122 polyether ether ketone polymer. They offer engineers a material solution for high-performance applications. They have a unique combination of properties such as high temperature resistance, low weight, mechanical strength, durability, excellent radiation, hydrolysis and chemical resistance, electrical insulation, abrasion and wear resistance, excellent barrier properties with high purity, flame retardant without the use of flame retardants, low toxicity of combustion products and low moisture absorption. The inherently flame-retardant films are easy to process.<\/h5>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":4416,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[160,163,156],"product_tag":[],"class_list":{"0":"post-5990","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-insulation","7":"product_cat-insulating-foils","8":"product_cat-flexible-electrical-insulation-materials","10":"first","11":"instock","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/5990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/4416"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=5990"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=5990"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=5990"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=5990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}