{"id":6033,"date":"2024-01-24T15:33:32","date_gmt":"2024-01-24T14:33:32","guid":{"rendered":"https:\/\/schupp.ch\/p\/kapton-hn-insulating-tubes-non-shrinking-class-c-200-c\/"},"modified":"2025-12-30T15:29:25","modified_gmt":"2025-12-30T14:29:25","slug":"kapton-hn-insulating-tubes-non-shrinking-class-c-200-c","status":"publish","type":"product","link":"https:\/\/schupp.ch\/en\/p\/kapton-hn-insulating-tubes-non-shrinking-class-c-200-c\/","title":{"rendered":"Kapton\u00ae HN insulating tubes, non-shrinking, class C (&gt; 200 \u00b0C)"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p><strong>Properties<\/strong><\/p>\n<ul>\n<li>Coiled insulating and protective conduit for applications in temperature class C<\/li>\n<li>Material: DuPont\u2122 Kapton\u00ae HN<\/li>\n<li>Inside diameters from 1.60 mm to 210 with wall thicknesses from 0.028 mm available.<\/li>\n<li>Outstanding mechanical properties.<\/li>\n<li>For applications in temperature class C up to 250 \u00b0C.<\/li>\n<li>Dielectric strength remains even when exposed to radiation<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Technical data<\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"7\" width=\"631\"><strong>Electrical properties<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"2\" width=\"222\"><strong>Properties<\/strong><\/td>\n<td colspan=\"3\" width=\"195\"><strong>Typical value for film 25 \u00b5m<\/strong><\/td>\n<td rowspan=\"2\" width=\"94\"><strong>Test condition<\/strong><\/td>\n<td rowspan=\"2\" width=\"120\"><strong>Test method<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"56\"><strong>-195 \u00b0C<\/strong><\/td>\n<td width=\"64\"><strong>25 \u00b0C<\/strong><\/td>\n<td width=\"74\"><strong>200 \u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"222\">short-term<\/td>\n<td width=\"56\"><\/td>\n<td width=\"64\"><\/td>\n<td width=\"74\"><\/td>\n<td width=\"94\"><\/td>\n<td width=\"120\"><\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Dielectric strength<\/td>\n<td width=\"43\">[kV]<\/td>\n<td width=\"56\">10,8<\/td>\n<td width=\"64\">7,0<\/td>\n<td width=\"74\">5,6<\/td>\n<td width=\"94\">60 Hz<\/td>\n<td width=\"120\">ASTM D 149-64<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"222\">Dielectric constant<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">3,5<\/td>\n<td width=\"74\">3,0<\/td>\n<td width=\"94\">1000 Hz<\/td>\n<td width=\"120\">ASTM D 150-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"222\">Loss factor<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">0,003<\/td>\n<td width=\"74\">0,002<\/td>\n<td width=\"94\">1000 Hz<\/td>\n<td width=\"120\">ASTM D 150-64T<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Contact resistance<\/td>\n<td width=\"43\">[\u03a9\/m]<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">1016<\/td>\n<td width=\"74\">1012<\/td>\n<td width=\"94\">&#8212;<\/td>\n<td width=\"120\">ASTM D 257-61<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"222\">Surface resistance [\u03a9\/square]<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">1016<\/td>\n<td width=\"74\">&#8212;<\/td>\n<td width=\"94\">50% relative humidity<\/td>\n<td width=\"120\">ASTM D 257-61<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Corona discharge voltage<\/td>\n<td width=\"43\">[V]<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">465<\/td>\n<td width=\"74\">&#8212;<\/td>\n<td width=\"94\">50% relative humidity<\/td>\n<td width=\"120\">ASTM D 1868-61T<\/td>\n<\/tr>\n<tr>\n<td width=\"180\">Insulation resistance<\/td>\n<td width=\"43\">[M\u03a9\/F]<\/td>\n<td width=\"56\">&#8212;<\/td>\n<td width=\"64\">100000<\/td>\n<td width=\"74\">&#8212;<\/td>\n<td width=\"94\"><\/td>\n<td width=\"120\">measured from a capacitor wound with 25 \u00b5m H foil\u00a00.05 \u00b5F<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"7\" width=\"632\"><strong>Physical properties<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" rowspan=\"2\" width=\"280\"><strong>Properties<\/strong><\/td>\n<td colspan=\"3\" width=\"191\"><strong>Typical value for film 25 \u00b5m<\/strong><\/td>\n<td rowspan=\"2\" width=\"161\"><strong>Test method<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"62\"><strong>-195 \u00b0C<\/strong><\/td>\n<td width=\"64\"><strong>25\u00b0 C<\/strong><\/td>\n<td width=\"65\"><strong>200 \u00b0C<\/strong><\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Tear strength (LR)<\/td>\n<td width=\"56\">[kg\/cm2]<br \/>\n[MPa]<\/td>\n<td width=\"62\">2,450<br \/>\n241<\/td>\n<td width=\"64\">1,750<br \/>\n172<\/td>\n<td width=\"65\">1,200<br \/>\n117<\/td>\n<td width=\"161\">ASTM D 882-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Yield strength (LR)<\/td>\n<td width=\"56\">[kg\/cm2]<br \/>\n[MPa]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">700<br \/>\n69<\/td>\n<td width=\"65\">420<br \/>\n41<\/td>\n<td width=\"161\">ASTM D 882-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Tension for 5% elongation (LR)<\/td>\n<td width=\"56\">[kg\/cm2]<br \/>\n[MPa]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">910<br \/>\n90<\/td>\n<td width=\"65\">600<br \/>\n59<\/td>\n<td width=\"161\">ASTM D 882-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Tear elongation (LR)<\/td>\n<td width=\"56\">[%]<\/td>\n<td width=\"62\">2<\/td>\n<td width=\"64\">70<\/td>\n<td width=\"65\">90<\/td>\n<td width=\"161\">ASTM D 882-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Train module (LR)<\/td>\n<td width=\"56\">[kg\/cm2]<br \/>\n[MPa]<\/td>\n<td width=\"62\">35&#8217;800<br \/>\n3&#8217;500<\/td>\n<td width=\"64\">30&#8217;000<br \/>\n2&#8217;950<\/td>\n<td width=\"65\">18,200<br \/>\n1,800<\/td>\n<td width=\"161\">ASTM D 882-64T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Impact resistance (D)<\/td>\n<td width=\"56\">[kg\/cm] [N\/m]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">6<br \/>\n0.6<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">DuPont\u2122 Pneumatic<br \/>\nImpact Test<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Folding resistance (MIT)<\/td>\n<td width=\"56\">Cycles<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">10&#8217;000<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 2176-63T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" width=\"223\">Tear resistance (Elmendorf)<\/td>\n<td width=\"56\">[g]<br \/>\n[mN]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">8<br \/>\n78<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 1922-61T<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Tear resistance (Graves)<\/td>\n<td width=\"52\"><\/td>\n<td width=\"56\">[g]<br \/>\n[N]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">510<br \/>\n5<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 1004-61<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Burst test (Mullen)<\/td>\n<td width=\"52\"><\/td>\n<td width=\"56\">[kg\/cm2]<br \/>\n[kPa]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">5.25<br \/>\n517<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 774-63T<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Density<\/td>\n<td width=\"52\"><\/td>\n<td width=\"56\">[Mg\/m2]<\/td>\n<td width=\"62\"><\/td>\n<td width=\"64\">1,42<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 1505-63T<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"280\">Coefficient of sliding friction film to film<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">0,42<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">ASTM D 1894-63<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\" width=\"280\">Refractive index (Becke Line)<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">1,78<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">Encyclopaedic Dictionary of Physics, Volume 1<\/td>\n<\/tr>\n<tr>\n<td width=\"171\">Grammage<\/td>\n<td width=\"52\"><\/td>\n<td width=\"56\">[m2\/kg]<\/td>\n<td width=\"62\">&#8211;<\/td>\n<td width=\"64\">28<\/td>\n<td width=\"65\">&#8211;<\/td>\n<td width=\"161\">Calculation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"631\"><strong>Thermal properties<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"176\"><strong>Properties<\/strong><\/td>\n<td width=\"194\"><strong>Typical value for film 25 \u00b5m<\/strong><\/td>\n<td width=\"138\"><strong>Test condition<\/strong><\/td>\n<td width=\"122\"><strong>Test method<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"176\">Melting point<\/td>\n<td width=\"194\">none<\/td>\n<td width=\"138\"><\/td>\n<td width=\"122\"><\/td>\n<\/tr>\n<tr>\n<td width=\"176\">Zero Strength Temperature*)<\/td>\n<td width=\"194\">815 \u00b0C<\/td>\n<td width=\"138\">1.4 kg\/cm2 (138 kPa) Load during 5 s<\/td>\n<td width=\"122\">Hot Bar (DuPont\u2122 Test)<\/td>\n<\/tr>\n<tr>\n<td width=\"176\">&nbsp;<\/p>\n<p>Softening temperature<\/td>\n<td width=\"194\">435 \u00b0C<br \/>\n525 \u00b0C<\/td>\n<td width=\"138\">25 \u00b5m<br \/>\n50-125 \u00b5m<\/td>\n<td width=\"122\">Weighted Probe on Heated Film (DuPont\u2122 Test)<\/td>\n<\/tr>\n<tr>\n<td width=\"176\">Thermal expansion coefficient<\/td>\n<td width=\"194\">2.0 x 10-5\/K<\/td>\n<td width=\"138\">-14 \u00b0C to 38 \u00b0C<\/td>\n<td width=\"122\">ASTM D 696-44<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"3\" width=\"176\">Thermal conductivity coefficient<br \/>\n[cal] [cm]<\/td>\n<td width=\"194\">3.72 x 10-4 [cm2][s][\u00b0C][0,156W\/m\/K]<\/td>\n<td width=\"138\">25 \u00b0C<\/td>\n<td rowspan=\"3\" width=\"122\">Model TC-1 000 Twin Heatmeter Comparative Tester<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">3.89 x 10-4 [cm2][s][\u00b0C][0,163W\/m\/K]<\/td>\n<td width=\"138\">75 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"194\">4.26 x 10-4 [cm2][s][\u00b0C][0,178W\/m\/K]<\/td>\n<td width=\"138\">200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"176\">Flammability<\/td>\n<td width=\"194\">self-extinguishing<\/td>\n<td width=\"138\">&#8211;<\/td>\n<td width=\"122\"><\/td>\n<\/tr>\n<tr>\n<td width=\"176\">heat sealable<\/td>\n<td width=\"194\">no<\/td>\n<td width=\"138\">&#8211;<\/td>\n<td width=\"122\"><\/td>\n<\/tr>\n<tr>\n<td width=\"176\">Heat capacity<\/td>\n<td width=\"194\">0.261 cal\/g\/\u00b0C (1092 J\/kg\/K)<\/td>\n<td width=\"138\">40 \u00b0C<\/td>\n<td width=\"122\">Differential calorimeter<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*) Temperature at which the film can withstand a tension of 0.014 MPas (20psi) for 5 s.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Item number:<br \/>\n<\/strong>Example: IRNKH0100\/005\/0500<br \/>\nIRNKH = master number<br \/>\n0100 = 1.00 mm diameter<br \/>\n005 = 0.05 mm wall thickness<br \/>\n0500 = 500 mm length<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>\u00a0<\/strong><\/p>\n<h5>Wound Insulation Tubes made of Kapton\u00ae are highly stable and can be used in the most demanding applications in the aerospace, aviation and automotive industries. It is used where high dielectric strength and mechanical strength are required despite low wall thicknesses. It is suitable for applications with the harshest environmental conditions.<\/h5>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":1139,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[118,303],"product_tag":[],"class_list":{"0":"post-6033","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-technical-hoses","7":"product_cat-coiled-insulating-pipes","9":"first","10":"instock","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"acf":[],"_links":{"self":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product\/6033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media\/1139"}],"wp:attachment":[{"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/media?parent=6033"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_brand?post=6033"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_cat?post=6033"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/schupp.ch\/en\/wp-json\/wp\/v2\/product_tag?post=6033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}