Temperature limiter type L06 / P06 / H06 / V06

P06, H06 and V06 are switches with surface-mounted enclosures, fully insulated, automatically resetting with Expoxy

P06 is equipped with connection pins, H06 and V06 are equipped with connection cables.

Switching type: NC contact L06 resetting Normally closed contact P06 resetting NC contact H06 resetting Normally closed contact V06 resetting
isolated: yes yes yes yes
Temperature
Nominal switching temperature (NST) [°C]
in 5 K steps
70 – 200 70 – 180
Tolerance range -Standard- Tol [ [K] ± 5
Switch-back temperature (RST below NST) UL [ [K] -35 ± 15
(defined RST on customer request) VDE [ °C] ≥ 35
Tension
max. Operating voltage range up to … 500 V AC / 28 VDC
Rated voltage AC [VAC] 250 (VDE), 277 (UL)
Current/switching cycles
Rated current AC – cos j = 1.0 [A] / [n] 10,0 / 10‘000
Rated current AC – cos j = 0.6 [A] / [n] 6,3 / 10‘000
Rated current AC – cos j = 1.0 [A] / [n] 25,0 / 2‘000
Rated voltage DC [V] 24
Max. Switching current DC [A] / [n] 40,0 / 10‘000
Other data
High-voltage resistance [kV] 2 3,75
Total bounce time [ms] < 1
Contact resistance (according to MIL-STD R5757) [mΩ] £ 50
Vibration resistance 10 … 60 Hz [m/s2] 100
Compressive strength of the switch housing [N] 600
Suitable for installation in protection class I + II I + II II
Impregnation resistance suitable
Available licences
please specify IEC, ENEC, VDE, UL,CSA, CQC IEC,ENEC,VDE,CQC
Dimensions (standard)
         
Diameter or dimension Ø d or l x b[mm] 10,0 17 x 11,0 17,0 x 11,0 26,0 x 13,5
Overall height h [mm] from 5,0 from 6,0 from 7,5 from 10,0
Thread (size x length) [Mx x mm] M4 x 5,0
Width across flats/ max. Torque [SW/Nm] 10,0 / 2 – / 3,0 – / 2,5
Standard stranded wire connection: 0,75 mm2/ AWG18 0,50 mm2/AWG 20