C05 |
S05 |
L05 |
F05 |
Switching type | NC contact C05 resetting | NC contact S05 resetting | NC contact L05 resetting | NC contact F05 resetting | ||
insulated: Housing | no | Yes | yes | yes | ||
Temperature | ||||||
Nominal switching temperature (NST) [°C] in 5K steps |
50 – 200 | |||||
Tolerance range -Standard- Tol [ [K] | ± 5 | |||||
Switch-back temperature (RST below NST) UL [K] VDE [ °C] |
-35 ± 15
≥ 35 |
|||||
Tension | ||||||
max. Operating voltage range up to … | 500 V AC / 14 V DC | |||||
Rated voltage AC [VAC] | 250 (VDE), 277 (UL) | |||||
Current/switching cycles | ||||||
Rated current AC – cos j = 1.0 [A] / [n] | 6,3 /10’000 | |||||
Rated current – cos j = 0.6 [A] / [n] | 4,0 / 10’000 | |||||
max. Switching current – cos j = 1.0 [A] / [n] | 10.0 / 3,000
20.0 / 300 |
|||||
Rated current AC – cos j = 0.4 [A] / [n] | 4,6 / 10’000 | |||||
max. Switching current AC- cos j = 0.4 [A] / [n] | 18,4 / 1‘000 | |||||
Rated voltage DC [A] / [n] | 12 | |||||
Max. Switching current DC [A] / [n] | 40,0 / 10‘000 | |||||
Other data | ||||||
High-voltage resistance [kV] | — | 2 | 2 | |||
Total bounce time [ms] | < 1 | |||||
Contact resistance (according to MIL-STD R5757) [mΩ] | £ 50 | |||||
Vibration resistance 10 … 60 Hz [m/s2] | 100 | |||||
Compressive strength of the switch housing [N] | 300 | |||||
Suitable for installation in protection class | I | I + II | I + II | |||
Impregnation resistance | suitable | |||||
Available licences | ||||||
please specify | IEC, ENEC, VDE, UL, CSA, CQC, CMJ | IEC, ENEC, VDE, UL, CSA, CQC | ||||
Dimensions (standard) | ||||||
Diameter Ø d [mm] | 11,0 | 11,4 | 12,0 | 11,4 | ||
Overall height (with standard connection) h [mm] | from 5,0 | from 5,4 | from 8,0 | from 6,5 | ||
Length of the insulation cap l [mm] | — | 19,0 | — | — | ||
Thread (size x length) [M x mm] | — | — | M6 x 8 | — | ||
Width across flats/ max. Torque [SW/Nm] | — | — | 13/8 | — | ||
Standard connection | Stranded wire: 0.5 mm2 / AWG 20 |
Hint
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.