Solid- and stranded Wires, triple insulated with FEP Teflon®, class F

0,00

 

Due to their dielectric strength, wires insulated several times with fluoroplastics allow the construction of compact transformers without intermediate insulation between the primary and secondary windings. This results in better magnetic coupling between the windings, which results in lower leakage inductances.

These wires are also ideal for applications in medical electrical equipment, as the breakdown voltage of the insulation is greater than 4250 volts, which is required by UL to protect people.

 

 

 

 

 

Art.-Nr.

 

Conductor material: tinned copper
Insulation: Teflon® (FEP)
Number of layers: 3
Standard color:
Temperature class: F (155° C)
Tensile strength: 20.7 N/mm2 (3000 psi)
Flammability: V-0
Conformity: UL OBJT2 File No. E206198 UL/IEC60950-1 (Ed.2), Annex U. UL 2601

IEC 61558-2-16, 60601-1 (Ed.3), 61010-1 (Ed.3), VDE Approval No. 136743: Class F

Solderability: suitable for reflow soldering due to temperature resistance
Insulation thickness/layer: 0.051 mm (0.002″) 0.076 mm (0.003″) 0.13 mm (0.005″)
Operating voltage: 1000 V 1000 V 1000 V
Breakdown voltage: approx. 9000 V approx. 12000 V approx. 15000 V

 

Dimensional tolerances
AWG AWG AWG 8 -18 + 0.051 / – 0.051 mm
AWG 18 – 24 + 0.038/ – 0.038 mm AWG 10 -24 + 0.038/ – 0.038 mm AWG 20 -30 + 0.025 / – 0.025 mm
AWG 25 – 40 + 0.025/ – 0.025 mm AWG 25 -36 + 0.025 / – 0.025 mm AWG —-

 

Dimensions
AWG Type Conductor Ø Outer Ø Weight* Type Conductor Ø Outer Ø Weight* Type Conductor Ø Outer Ø Weight*
[mm] [mm] [kg/km] [mm] [mm] [kg/km] [mm] [mm] [kg/km]
10 T10A37FXXX-3 2,718 3,175 47,63 T10A37FXXX-5 2,718 3,480 51,18
12 T12A19FXXX-3 2,189 2,647 31,82 T12A19FXXX-5 2,189 2,951 34,77
14 T14A19FXXX-3 1,725 2,182 20,67 T14A19FXXX-5 1,725 2,487 23,12
16 T16A01FXXX-3 1,290 1,748 14,02 T16A01FXXX-5 1,290 2,052 16,04
16 T18A19FXXX-3 1,369 1,826 13,68 T16A19FXXX-5 1,369 2,131 15,77
18 T18A01FXXX-2 1,024 1,252 8,56 T18A01FXXX-3 1,024 1,481 9,30 T18A01FXXX-5 1,024 1,786 11,03
18 T18A19FXXX-2 1,209 1,514 10,16 T18A19FXXX-3 1,209 1,666 11,01 T18A19FXXX-5 1,209 1,971 12,93
20 T20A01FXXX-2 0,813 1,118 6,61 T20A01FXXX-3 0,813 1,270 6,25 T20A01FXXX-5 0,813 1,575 7,75
20 T20A19FXXX-2 0,978 1,283 6,77 T20A19FXXX-3 0,978 1,435 7,49 T20A19FXXX-5 0,978 1,740 9,17
22 T22A01FXXX-2 0,643 0,871 3,72 T22A01FXXX-3 0,643 1,100 4,27 T22A01FXXX-5 0,643 1,405 6,44
22 T20A19FXXX-2 0,749 1,054 4,42 T22A19FXXX-3 0,749 1,207 5,02 T22A19FXXX-5 0,749 1,511 4,17
24 T24A01FXXX-2 0,511 0,815 2,52 T24A01FXXX-3 0,511 0,968 2,99 T24A01FXXX-5 0,511 1,273 4,81
24 T24A19FXXX-2 0,615 0,919 2,99 T24A19FXXX-3 0,615 1,072 3,53 T24A19FXXX-5 0,615 1,377 3,21
25 T25A01FXXX-2 0,455 0,759 2,08
26 T26A01FXXX-2 0,404 0.709 1,73 T26A01FXXX-3 0,404 0,861 2,14 T26A01FXXX-5 0,404 1,166 3,21
26 T26A19FXXX-3 0,483 0,940 2,46 T26A19FXXX-5 0,483 1,245 3,60
27 T27A01FXXX-2 0,361 0,665 1,44
28 T28A01FXXX-2 0,320 0,625 1,22 T28A01FXXX-3 0,320 0,777 1,58 T28A01FXXX-5 0,320 1,082 2,56
28 T28A19FXXX-3 0,386 0,843 1,82 T28A19FXXX-5 0,386 1,148 2,87
29 T29A01FXXX-2 0,287 0,592 1,04 —- —-
30 T30A01FXXX-2 0,254 0,559 0,88 T30A01FXXX-3 0,254 0,711 1,22 T30A01FXXX-5 0,254 1,02 2,13
31 T31A01FXXX-2 0,226 0,531 0,76
32 T32A01FXXX-2 0,203 0,508 0,67
33 T33A01FXXX-2 0,180 0,485 0,58
34 T34A01FXXX-2 0,160 0,465 0,51
35 T35A01FXXX-2 0,142 0,447 0,45
36 T36A01FXXX-2 0,127 0,432 0,41 —- —-