Polyimide (Kapton®) Solid- and stranded Wires

0,00

 

Polyimides are often non-melting and chemically very resistant, even to many solvents. Polyimides are used in electrical engineering/electronics due to their heat resistance, low outgassing, radiation resistance and insulating properties in the form of light brown, semi-transparent films. High continuous operating temperatures of up to 230 °C and short-term temperatures of up to 400 °C are possible.

 

 

Kapton® – Solid- and stranded Wires, Cu silver-plated, 250 V

Details

 

Kapton® – Solid- and stranded Wires, Cu silver-plated, 600 V

Details

 

Kapton® – Solid- and stranded Wires, Cu silver-plated, 1000 V

Details

 

Kapton® / FEP insulated wires and strands according to UL Styles 5466

Details

 

 

 

Art.-Nr.

Kapton® wires & strands, silver-plated copper, 250 V

 

Insulation: 3 layers of polyimide film (Kapton®) 25 µm, with adhesive 40 µm flame-retardant, low smoke emission
Conductor: silver-plated copper (SPC), silver-plated copper alloy (SPCA)
Operating voltage: 250 VAC
Test voltage: 2500 VAC
Temperature range: -65 to +200 °C
Colors: natural color or color black, brown, red, orange, yellow, green, blue, violet, grey, white, pink by ‘painting’ or Teflon-based spiral paint. The color can fade at high temperatures and may also cause the cores to stick together (in the case of full coloring/lacquering).

 

Dimensions:

Size Conductor Insulated wire
Master number AWG Cross cut Structure Wire Ø DC current resistance at 20°C Outer Ø Tolerance Weight Current strength at 40°C
[mm2] [mm] [W / km] [mm] [mm] [kg/km] [A]
SLPT3207SA 32 0,035 7 x 0,08 0,24 670 0,50 ± 0,05 0,50 3
SDPT3001SA 30 0,049 1 x 0,25 0,25 417 0,51 ± 0,05 0,75 5
SLPT3007SA 30 0,057 7 x 0,10 0,30 385 0,56 ± 0,05 0,75 5
SDPT2801SA 28 0,080 1 x 0,32 0,32 263 0,58 ± 0,05 1,1 7
SLPT2807SA 28 0,089 7 x 0,13 0,38 244 0,64 ± 0,05 1,1 8
SDPT2601S 26 0,126 1 x 0,40 0,40 137 0,66 ± 0,05 1,8 10
SLPT2619S 26 0,155 19 x 0,10 0,48 122 0,77 ± 0,05 1,8 11
SDPT2401S 24 0,204 1 x 0,51 0,51 86,0 0,77 ± 0,05 2,7 12
SLPT2419S 24 0,241 19 x 0,13 0,60 77,4 0,86 ± 0,05 2,7 13
SDPT2201S 22 0,322 1 x 0,64 0,64 54,1 0,90 ± 0,05 4,1 16
SLPT2219S 22 0,382 19 x 0,16 0,76 48,5 1,06 ± 0,05 4,1 17
SDPT2001S 20 0,515 1 x 0,81 0,81 33,8 1,07 ± 0,05 6,3 20
SLPT2019S 20 0,597 19 x 0,20 0,97 29,9 1,27 ± 0,07 6,3 22
SLPT1819S 18 0,963 19 x 0,25 1,21 19,0 1,53 ± 0,07 9,4 29
SLPT1619S 16 1,229 19 x 0,29 1,36 14,8 1,69 ± 0,07 11,6 35

These figures are approximate and may change at any time.

 

Item number:

= Master number Ladder Color

 

Manager

S = silver-plated copper SA = silver-plated copper alloy

 

Color

ff = natural colors (NT), red (RT), blue (BL), black (SW), white (WS), green (GN),
brown (BR), violet (VI), orange (OR), yellow (GE), grey (GR), pink (RS),

 

Example:

SLPT3207SA SLPT3207 = master number SA = silver-plated copper alloy SW = black

 

 

Kapton® wires & strands, Cu silver-plated, 600 V

 

Insulation: 4 layers of polyimide film (Kapton®) 25 µm, with adhesive 40 µm
Flame-retardant, low smoke development
Conductor: silver-plated copper (SPC),
Silver-plated copper alloy (SPCA)
Operating voltage: 600 VAC
Test voltage: 3000 VAC
Temperature range: -65 to +200 °C
Colors: natural color or color black, brown, red, orange, yellow, green, blue, violet, grey, white, pink by ‘painting’ or Teflon-based spiral paint. The color can fade at high temperatures and may also cause the cores to stick together (in the case of full coloring/lacquering).

 

Correction factor of the current load depending on the ambient temperature:
°C 20 40 60 100 120 140 160 180
Factor 1,08 1,0 0,92 0,84 0,75 0,65 0,42 0,28

 

Dimensions:

Size Conductor Insulated wire
Master number AWG Cross cut Structure Wire Ø DC resistance at 20°C Outer Ø Tolerance Weight Current strength at 40°C
[mm2] [mm] [W / km] [mm] [mm] [kg/km] [A]
SLP3207SA 32 0,035 7 x 0,08 0,24 670 0,57 ± 0,05 0,60 3
SDP3001SA 30 0,049 1 x 0,25 0,25 417 0,58 ± 0,05 0,80 5
SLP3007SA 30 0,057 7 x 0,10 0,30 385 0,63 ± 0,05 0,90 5
SDP2801SA 28 0,080 1 x 0,32 0,32 263 0,65 ± 0,05 1,2 7
SLP2807SA 28 0,089 7 x 0,13 0,38 244 0,71 ± 0,05 1,3 8
SDP2601S 26 0,126 1 x 0,40 0,40 137 0,73 ± 0,05 1,9 10
SLP2619SA 26 0,155 19 x 0,10 0,48 146 0,81 ± 0,05 1,9 11
SLP2619S 26 0,155 19 x 0,10 0,48 122 0,81 ± 0,05 1,9 11
SDP2401S 24 0,204 1 x 0,51 0,51 86,0 0,81 ± 0,05 2,8 12
SLP2419SA 24 0,241 19 x 0,13 0,60 93,1 0,93 ± 0,05 2,8 13
SLP2419S 24 0,241 19 x 0,13 0,60 93,1 0,93 ± 0,05 2,8 13
SDP2201S 22 0,322 1 x 0,64 0,64 54,1 0,94 ± 0,05 4,2 16
SLP2219S 22 0,382 19 x 0,16 0,76 48,5 1,10 ± 0,05 4,2 17
SDP2001S 20 0,515 1 x 0,81 0,81 33,8 1,11 ± 0,05 6,5 20
SLP2019S 20 0,597 19 x 0,20 0,97 29,9 1,31 ± 0,07 6,5 22
SLP1819S 18 0,963 19 x 0,25 1,21 19,0 1,57 ± 0,07 9,9 29
SLP1619S 16 1,229 19 x 0,29 1,36 14,8 1,73 ± 0,07 13,0 35
SLP1419S 14 1,870 19 x 0,36 1,70 9,42 2,19 ± 0,10 20,0 53
SLP1237S 12 2,976 37 x 0,32 2,24 6,20 2,63 ± 0,10 29,0 66
SLP1037S 10 4,650 37 x 0,40 2,82 3,90 3,21 ± 0,15 45,0 82

These figures are approximate and may change at any time.

 

Item number:

= Master number Ladder Color

 

Manager

S = silver-plated copper SA = silver-plated copper alloy

 

Color

ff = natural colors (NT), red (RT), blue (BL), black (SW), white (WS), green (GN),
brown (BR), violet (VI), orange (OR), yellow (GE), grey (GR), pink (RS),

 

Example:

SLP3207SA SLP3207 = master number SA = silver-plated copper alloy SW = black

 

 

Kapton® wires & strands, Cu silver-plated, 1000 V

 

Insulation: 6 layers of polyimide film (Kapton®) 25 µm, with adhesive 40 µm flame-retardant, low smoke emission
Conductor: silver-plated copper (SPC) silver-plated copper alloy (SPCA)
Operating voltage: 1000 VAC
Test voltage: 2500 VAC
Temperature range: -65 to +200 °C
Colors: natural color or color black, brown, red, orange, yellow, green, blue, violet, grey, white, pink by ‘painting’ or Teflon-based spiral paint. The color can fade at high temperatures and may also cause the cores to stick together (with full coloring / painting)

 

Correction factor of the current load as a function of the ambient temperature:
°C 20 40 60 100 120 140 160 180
Factor 1,08 1,0 0,92 0,84 0,75 0,65 0,42 0,28

 

Dimensions:

Size Conductor Insulated wire
Master number AWG Cross cut Structure Wire Ø DC resistance at 20°C Outer Ø Tolerance Weight Current strength at 40°C
[mm2] [mm] [W / km] [mm] [mm] [kg/km] [A]
SDPP2601S 26 0,126 1 x 0,40 0,40 137 0,84 ± 0,05 2,2 10
SLPP2619SA 26 0,155 19 x 0,10 0,48 146 0,95 ± 0,05 2,2 11
SDPP2401S 24 0,204 1 x 0,51 0,51 86,0 0,95 ± 0,05 3,1 12
SLPP2419SA 24 0,241 19 x 0,13 0,60 93,1 1,07 ± 0,05 3,1 13
SDPP2201S 22 0,322 1 x 0,64 0,64 54,1 1,08 ± 0,05 4,6 16
SLPP2219S 22 0,382 19 x 0,16 0,76 48,5 1,24 ± 0,07 4,6 17
SDPP2001S 20 0,515 1 x 0,81 0,81 33,8 1,25 ± 0,07 6,9 20
SLPP2019S 20 0,597 19 x 0,20 0,97 29,9 1,45 ± 0,07 6,9 22
SLPP1819S 18 0,963 19 x 0,25 1,21 19,0 1,71 ± 0,07 11 29
SLPP1619S 16 1,229 19 x 0,29 1,36 14,8 1,87 ± 0,07 13 35
SLPP1419S 14 1,870 19 x 0,36 1,70 9,42 2,36 ± 0,10 21 53
SLPP1237S 12 2,976 37 x 0,32 2,24 6,20 2,80 ± 0,10 32 66
SLPP1037S 10 4,650 37 x 0,40 2,82 3,90 3,38 ± 0,15 49 82

These figures are approximate and may change at any time.

 

Item number:

= Master number Ladder Color

 

Manager

S = silver-plated copper SA = silver-plated copper alloy

 

Color

ff = natural colors (NT), red (RT), blue (BL), black (SW), white (WS), green (GN),
brown (BR), violet (VI), orange (OR), yellow (GE), grey (GR), pink (RS),

 

Example:

SDPP2601SW SDPP2601 = master number SA = silver-plated copper alloy SW = black

 

 

Kapton® / FEP insulated wires and strands according to style UL5466

 

Style UL5466, including AVLV8 Canadian Territories Approval

 

Application:

UL-approved high-temperature device wiring

 

Technical data

Master number ladder Conductor diameter Resistance Weight
AWG Structure Cross section Diameter min. max. nom. nom.
n x AWG [mm2] [Ω/km] [kg/km]
SLPKUL5466/2607 26 7 x 0,16 0,14 0,48 0,70 0,85 128 1,75
SLPKUL5466/2407 24 7 x 0,203 0,23 0,60 0,85 1,00 81,0 2,70
SLPKUL5466/2207 22 7 x 0,254 0,35 0,76 1,00 1,20 59,4 3,93
SLPKUL5466/2219 22 19 x 0,16 0,38 0,80 1,00 1,20 51,6 4,20
SLPKUL5466/2007 20 7 x 0,32 0,56 0,96 1,18 1,32 32,81 6,04
SLPKUL5466/2019 20 19 x 0,203 0,61 1,00 1,20 1,40 31,4 6,5

 

Item number:

Master number Ladder Color

Color:

ff = natural colors (NT), red (RT), blue (BL), black (SW), white (WS), green (GN),
brown (BR), violet (VI), orange (OR), yellow (GE), grey (GR), pink (RS),

Example:

SLPKUL5466/2607SW SLPKUL5466/2607 = master number SW = black