C06 |
C06HT |
S06 |
S06HT |
B06 |
F06 |
Switching type: | Normally closed contact | Normally closed contact | Normally closed contact | Normally closed contact | ||
Automatically resetting | ||||||
C06 | C06HT | S06 | S06HT | B06 | F06 | |
insulated: Insulation cap/housing | no | Yes | Yes | yes | ||
Temperature | ||||||
Nominal switching temperature (NST), [°C] in 5 K steps |
70 – 200 | 205- 250 | 70 – 200 | 50 -250 | 70 – 200 | |
Tolerance range -Standard- Tol [ [K] | ± 5 | |||||
Switch-back temperature (RST below NST) UL [ [K] VDE [ °C] |
-35 ± 15
≥ 35 |
|||||
Tension | ||||||
max. Operating voltage range AC to … [VAC] | 500 V AC / 28 V DC | |||||
Rated voltage AC [VAC] | 250 (VDE), 277 (UL) | |||||
Current/switching cycles | ||||||
Rated current AC – cos j = 1.0 [A] / [n] | 10,0 / 10’000 | |||||
Rated current AC – cos j = 0.6 [A] / [n] | 6,3 / 10’000 | |||||
Max. Switching current AC – cos j = 1.0 [A] / [n] | 25,0 / 2‘000 | |||||
Rated voltage DC [V] | 24 V | |||||
Max. Switching current DC [A] / [n] | 40,0 / 10‘000 | |||||
Other data | ||||||
High-voltage resistance [kV] | — | 2 | ||||
Total bounce time [ms] | < 1 | |||||
Contact resistance (according to MIL-STD R5757) [mΩ] | ≤ 50 | |||||
Vibration resistance 10 … 60 Hz [m/s2] | 100 | |||||
Compressive strength of the switch housing [N] | 600 | |||||
Suitable for installation in protection class | I | I + II | ||||
Impregnation resistance | suitable | |||||
Available licences | ||||||
please specify | IEC, ENEC, VDE, UL, CSA, CQC | |||||
Dimensions (standard) | ||||||
C06 | C06HT | S06 | S06HT | B06 | F06 | |
Diameter or Ø d or l x b[mm]
Dimension |
9,0 | 9,4 | 9,4 | 10,0 | ||
Overall height h [mm] | from 6.3 | from 7,1 | from 6,7 | from 7,5 | from 6.7 | from 5,0 |
Length of insulation cap l [mm] | — | 16,0 | — | — | ||
Standard stranded wire connection: | 0.75 mm2/AWG18 |
Hint
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.