Temperature limiter type C06 / C06HT / S06 / S06HT / B06 / F06; 4.0 – 25 A

0,00

C06 S06 and L06 are switches with connection cables, automatically resetting

S06 with epoxy, fully insulated with Mylar®Nomex® cap

L06 with aluminum screw-on housing

 

Possible applications in switch cabinets, on motor housings or heat sinks

Art.-Nr.
C06
C06HT
S06
S06HT
B06
F06

 

Switching type: Normally closed contact Normally closed contact Normally closed contact Normally closed contact
Automatically resetting
C06 C06HT S06 S06HT B06 F06
insulated: Insulation cap/housing no Yes Yes yes
Temperature
Nominal switching temperature (NST), [°C]
in 5 K steps
70 – 200 205- 250 70 – 200 50 -250 70 – 200
Tolerance range -Standard- Tol [ [K] ± 5
Switch-back temperature (RST below NST) UL [ [K]
VDE [ °C]
-35 ± 15

≥ 35

Tension
max. Operating voltage range AC to … [VAC] 500 V AC / 28 V DC
Rated voltage AC [VAC] 250 (VDE), 277 (UL)
Current/switching cycles
Rated current AC – cos j = 1.0 [A] / [n] 10,0 / 10’000
Rated current AC – cos j = 0.6 [A] / [n] 6,3 / 10’000
Max. Switching current AC – cos j = 1.0 [A] / [n] 25,0 / 2‘000
Rated voltage DC [V] 24 V
Max. Switching current DC [A] / [n] 40,0 / 10‘000
Other data
High-voltage resistance [kV] 2
Total bounce time [ms] < 1
Contact resistance (according to MIL-STD R5757) [mΩ] ≤ 50
Vibration resistance 10 … 60 Hz [m/s2] 100
Compressive strength of the switch housing [N] 600
Suitable for installation in protection class I I + II
Impregnation resistance suitable
Available licences
please specify IEC, ENEC, VDE, UL, CSA, CQC
Dimensions (standard)
C06 C06HT S06 S06HT B06 F06
Diameter or Ø d or l x b[mm]

Dimension

9,0 9,4 9,4 10,0
Overall height h [mm] from 6.3 from 7,1 from 6,7 from 7,5 from 6.7 from 5,0
Length of insulation cap l [mm] 16,0
Standard stranded wire connection: 0.75 mm2/AWG18

 

Hint

The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.