C09 |
S09 |
L09 |
F09 |
Switching type | NO contact C09 resetting |
NO contact S09 resetting |
NO contact L09 resetting |
NO contact F09 resetting |
|||
insulated: Housing | no | Yes | yes | yes | |||
Temperature | |||||||
Nominal switching temperature (NST), [°C]
in 5K steps |
60 – 180 | ||||||
Tolerance range -Standard- Tol [ [K] | ± 5 | ||||||
Switch-back temperature (RST below NST) UL [ K] | -35 ± 15 | ||||||
VDE [ °C] | ≥ 35 | ||||||
Tension | |||||||
max. Operating voltage range AC to … [VAC] | 500 V | ||||||
Rated voltage AC [VAC] | 250 (VDE), 277 (UL) | ||||||
Current/switching cycles | |||||||
Rated current AC – cos j = 1.0 [A] / [n] | 6,3 /10’000 | ||||||
max. Switching current – cos j = 0.6 [A] / [n] | 4,0 / 10‘000 | ||||||
Other data | |||||||
High-voltage resistance [kV] | — | 2 | 2 | ||||
Total bounce time [ms] | < 1 | ||||||
Contact resistance (according to MIL-STD R5757) [mΩ] | £ 50 | ||||||
Vibration resistance 10 … 60 Hz [m/s2] | 100 | ||||||
Compressive strength of the switch housing [N] | 300 | ||||||
Suitable for installation in protection class | I | I + II | I + II | ||||
Impregnation resistance | suitable | ||||||
Available licences | |||||||
please specify | IEC, ENEC, VDE, UL, CSA, CQC, CMJ | IEC, ENEC, VDE, UL, CSA, CQC | |||||
Dimensions (standard) | |||||||
Diameter Ø d [mm] | 11,0 | 11,4 | 12,0 | 11,4 | |||
Overall height (with standard connection) h [mm] | from 5,0 | from 5,4 | from 8,0 | from 6,5 | |||
Length of the insulation cap l [mm] | — | 19,0 | — | — | |||
Thread (size x length) [M x mm] | — | — | M6 x 8 | — | |||
Width across flats/ max. Torque [SW/Nm] | — | — | 13/8 | — | |||
Standard stranded wire connection: | 0.5 mm2 / AWG 20 |
Hint
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.