C09 |
S09 |
L09 |
F09 |
![]() |
![]() |
![]() |
![]() |
| Switching type | NO contact C09 resetting |
NO contact S09 resetting |
NO contact L09 resetting |
NO contact F09 resetting |
|||
| insulated: Housing | no | Yes | yes | yes | |||
| Temperature new | |||||||
| Nominal switching temperature (NST), [°C] in 5K steps | 60 – 180 | ||||||
| Tolerance range -Standard Tol [ [K] | ± 5 | ||||||
| Reverse Switch Temperature (RST below NST) UL [ K] | -35 ± 15 | ||||||
| Reverse Switch Temperature (RST below NST) VDE [ °C] | ≥ 35 | ||||||
| Tension | |||||||
| max. Operating voltage range AC to [VAC] | 500 V | ||||||
| Rated voltage AC [VAC] | 250 (VDE), 277 (UL) | ||||||
| Current/switching cycles | |||||||
| Rated current AC – cos j = 1.0 [A] / [n] | 6,3 /10’000 | ||||||
| max. Switching current – cos φ= 0.6 [A] / [n] | 4,0 / 10’000 | ||||||
| Additional specifications | |||||||
| High-voltage strength [kV] | — | 2 | 2 | ||||
| Total bounce time [ms] | < 1 | ||||||
| Contact resistance (according to MIL-STD R5757) [mΩ] | < 50 | ||||||
| Vibration resistance 10 … 60 Hz [m/s2] | 100 | ||||||
| Compressive strength of the switch housing [N] | 300 | ||||||
| Suitable for installation in protection class | I | I + II | I + II | ||||
| Impregnation resistance | suitable | ||||||
| Available Licenses and Approvals | |||||||
| please specify | IEC, ENEC, VDE, UL, CSA, CQC, CMJ | IEC, ENEC, VDE, UL, CSA, CQC | |||||
| Dimensions (standard) | |||||||
| Diameter Ø d [mm] | 11,0 | 11,4 | 12,0 | 11,4 | |||
| Installation height (with standard connection) h [mm] | from 5.0 | from 5.4 | from 8.0 | from 6.5 | |||
| Length of insulation cap l [mm] | — | 19,0 | — | — | |||
| Thread (size x length ) [M x mm] | — | — | M6 x 8 | — | |||
| Width across flats/ max. Torque [SW/Nm] | — | — | 13/8 | — | |||
| Standard stranded wire connection: | 0.5 mm2 / AWG 20 | ||||||
| C09 | S09 | L09 | F09 |
![]() |
![]() |
![]() |
![]() |
Note
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.