Thermal Protetors three-pole for star point type SY6 / CY6 / SYH / CYH; 4.0 – 25 A

0,00

 

CY6, SY6, CYH and SYH are normally closed contacts for use in the neutral point of three-phase motors, automatically resetting, with epoxy

 

CY6 , CYH without insulation

 

SY6 , SYH is insulated with Mylar®-Nomex® cap.

 

Art.-Nr.
SY6
CY6
SYH
CYH

 

Switching type NC contact SY6 resetting NC contact CY6 resetting NC contact SYH resetting NC contact CYH resetting
insulated: Housing yes no yes no
Temperature
Nominal switching temperature (RST below NST), in 5 K steps [°C] 70 – 200 70 – 180
Tolerance range -Standard-Tol [ [K] ± 5 ± 10
Reverse Switch Temperature (RST below NST) UL (°C) -35 ± 15
( defined RST possible on customer request) VDE (°C) ≥ 35
Tension
max. AC operating voltage range up to AC] 440 440
Rated voltage AC (VAC) 3 x 440 V 50/60 Hz 3 x 440 V 50/60 Hz
Current / switching cycles
Rated current cos φ = 1.0 (A) / (n) 2,5 / 10’000 2,5 / 10’000
max. Switching current – cos φ = 1.0 (A) / (n) 6,3 / 3’000 12 / 3’000
Additional specifications
Total bounce time (ms) < 1
Contact resistance (according to MIL-STD R5757 (mΩ) < 50
Vibration resistance 10 … 60 Hz (m/s2) 100
Compressive strength of the switch housing (N) 600
Suitable for installation in protection class I +II I I + II I
Impregnation resistance suitable
Available Licenses and Approvals
please specify UL, CSA, CQC
Dimensions (standard)
Diameter Ø d [mm ] 9,0 9,4 9,0 9,4
Overall height h [mm ] from 6.3 from 6.7 from 6.3 from 6.7
Length of insulation cap hl [mm ] 16,0 16,0
Standard stranded wire connection: 0.5 mm2 / AWG 20 1.0 mm2 / AWG 18
Functional diagram

 

SY6 CY6 SYH CYH

 

Note

The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.

We will be pleased to advise you.