Three-pole temperature limiter for star point type SY6 / CY6 / SYH / CYH; 4.0 – 25 A

0,00

CY6, SY6, CYH and SYH are NC contacts for use in the neutral point of three-phase motors, automatically resetting, with epoxy

CY6 , CYH without insulation

SY6 , SYH is insulated with Mylar®-Nomex® cap.

Art.-Nr.
SY6
CY6
SYH
CYH

 

Switching type NC contact SY6 resetting NC contact CY6 resetting NC contact SYH resetting NC contact CYH resetting
insulated: Housing yes no Yes no
Temperature
Nominal switching temperature (NST), in 5 K steps [°C] 70 – 200 70 – 180
Tolerance range -Standard- Tol [ [K] ± 5 ± 10
Switch-back temperature (RST below NST) UL [°C] -35 ± 15
( defined RST possible on customer request) VDE [°C] ≥ 35
Tension
max. AC operating voltage range up to [VAC] 440 440
Rated voltage AC [VAC] 3 x 440 V 50/60 Hz 3 x 440 V 50/60 Hz
Current / switching cycles
Rated current- cos j = 1.0 [A] / [n] 2,5 / 10’000 2,5 / 10’000
max. Switching current – cos j = 1.0 [A] / [n 6,3 / 3‘000 12 / 3‘000
Other data
Total bounce time [ms] < 1
Contact resistance (according to MIL-STD R5757 [mΩ] £ 50
Vibration resistance 10 … 60 Hz [m/s2] 100
Compressive strength of the switch housing [N] 600
Suitable for installation in protection class I +II I I + II I
Impregnation resistance suitable
Available licences
please specify UL, CSA, CQC
Dimensions (standard)
Diameter Ø d [mm] 9,0 9,4 9,0 9,4
Overall height h [mm] from 6.3 from 6,7 from 6.3 from 6,7
Length of the insulation cap hl [mm] 16,0 16,0
Standard connection Stranded wire: 0.5 mm2 / AWG 20 1.0 mm2 / AWG 18
Functional diagram

 

Hint

The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.