CR6 |
SR6 |
![]() |
![]() |
Switch type: | NC contact CR6 self-retaining | NC contact SR6 latching |
isolated: | no | yes |
Temperature | ||
Nominal switching temperature (NST), in 5 K steps [°C] | 60 – 180 | |
Tolerance range ≤ 140 °C Tol [ [K] | ± 5 | |
Tolerance range ≥140 °C Tol [ [K] | ± 10 | |
Reverse Switch Temperature (RST below NST) UL [ [K] | ≥ 35 | |
(defined RST on customer request) VDE [ °C] | ≥ 35 | |
Tension | ||
Operating voltage range up to … | 250 V | |
Rated voltage AC [VAC] | 120/230 (VDE), 250 (UL) | |
Current/switching cycles | ||
Rated current – cos φ = 1.0 [A] / [n] | 10,0 / 1’000 | |
Rated current -cos φ = 0.6 [A] / [n] | 6,3 / 1’000 | |
max. Switching current cos φ = 1.0 [A] / [n] | 25,0 / 1’000 | |
Additional specifications | ||
High-voltage strength [kV] | — | 2 |
Total bounce time [ms] | < 1 | |
Contact resistance (according to MIL-STD R5757) [mΩ] | < 50 | |
Vibration resistance 10 … 60 Hz [m/s2] | 100 | |
Compressive strength of the switch housing [N] | 600 | |
Available Licenses and Approvals | ||
please specify | IEC, ENEC, VDE, UL, CSA, CQC | |
Dimensions (standard) | ||
Diameter Ø d [mm] | 9,0 | 9,4 |
Overall height h [mm] | from 6.3 | from 6.7 |
Length of insulation cap l [mm] | — | 17,0 |
Standard stranded wire connection: | 0.75 mm2/AWG 18 | |
Functional diagram | ||
The ceramic resistor connected in parallel to the switch heats up after the contact opens, which keeps the contact in the open state.
|
CR6 | SR6 |
![]() |
![]() |
Note
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.
We will be pleased to advise you.