Switching type: | Opener | Closer | Opener | Opener | Closer | Opener |
Automatically resetting | ||||||
C01 | C02 | C01HT | S01 | S02 | S01HT | |
Insulated: Insulation cap | no | no | no | yes | yes | yes |
Temperature | ||||||
Nominal switching temperature (NST ), [°C] in 5 K steps |
60 -200 | 70 -200 | 205 – 250 | 60 -200 | 70 -200 | 205 – 250 |
Tolerance range -Standard- Tol [ [K] | ± 2,5 /± 5 | ± 5 | ± 10 | ± 2,5 /± 5 | ± 5 | ± 10 |
Switch-back temperature (RST below NST) UL [K]
VDE [°C] |
-35 ± 15
≥ 35 |
|||||
Tension | ||||||
max. Operating voltage range up to … | 500 V AC / 14 V DC | |||||
Rated voltage AC [VAC] | 250 ( VDE), 277 (UL) | |||||
Current/switching cycles | ||||||
Rated current – cos j = 1.0 [A] / [n] | 2,5 / 1‘000 | |||||
Nennstrom – cos j = 0,6 [A] / [n] | 1,6 / 10‘000 | |||||
max. Switching current – cos j = 1.0 [A] / [n] | 6,3 / 3‘000
7,5 / 300 |
|||||
Rated current – cos j = 0.4 [A] / [n] | 1,8 / 10‘000 | |||||
max. Switching current – cos j = 0.4 [A] / [n] | 7,2 / 1‘000 | |||||
Rated voltage DC [V] | 12 | |||||
Max. Switching current DC [A] / [n] | 40,0 / 1‘000 | |||||
Other data | ||||||
High-voltage resistance [kV] | — | 2 | ||||
Total bounce time [ms] | < 1 | |||||
Contact resistance (according to MIL-STD R5757) [mΩ] | £ 50 | |||||
Vibration resistance 10 … 60 Hz [m/s2] | 100 | |||||
Compressive strength of the switch housing [N] | 450 | |||||
Suitable for installation in protection class | I | I + II | ||||
Impregnation resistance | suitable | |||||
Available licences | ||||||
please specify |
IEC, ENEC, VDE, UL, CSA, CQC,CMJ | IEC, ENEC, VDE, CQC
(UL (appr. £ 230°C) |
IEC, ENEC, VDE, UL, CSA, CQC,CMJ | IEC, ENEC, VDE, CQC,
(UL(appr.£230°C) |
||
Dimensions (standard) | ||||||
Diameter Ø d [mm] | 9,0 | 9.0 | 9,4 | 9,5 | ||
Overall height h [mm] | from 3,9 | from 4,4 | from 4,7 | from 4,3 | from 4,8 | |
Length of insulation cap l [mm] | — | — | 15 | 20,5 | ||
Standard stranded wire connection: | 0,25 mm2/AWG 22 | |||||
Current dependency charateristics | ||||||
The special feature of the 01 and 02 series is that they are temperature-sensitive switches. In their rated operation (rated current), they exhibit very low self-heating due to the current. Therefore, a switching point reduction takes place at most within the nominal switching temperature tolerance. |
Temperature limiter type C01 / C02 / C01HT / S01 / S02 / S01HT
C01, C02, C01HT, S01, S02 and S02HT are switches with connection cables, automatically resetting with or without Expoxy S02 is insulated with Mylar®-Nomex® cap
S01HT is insulated with PTFE cap
- Possible applications in switch cabinets, on motor housings or heat sinks