Type / design |
|||
|
SH5 | CXO |
|
Switch type: | NC contact CH5 resetting | NC contact SH5 resetting | NC contact CXO resetting | NC contact SXO resetting | |||
isolated: | no | Yes | no | yes | |||
Temperature | |||||||
Nominal switching temperature (NST), in 5 K steps |
[°C] | 120 – 180 | 70 – 180 | ||||
Tolerance range -Standard- Tol [[K] | ± 10K | ||||||
reset temperature) ( RST below half NST |
U L[K] | ≥ 35 | |||||
(defined RST possible at customer request) |
VDE [°C] | ≥ 35 | |||||
Tension | |||||||
max. Operating voltage range up to … | 500 V AC / 14 V DC | ||||||
Rated voltage AC [VAC] | 250 V | ||||||
Current/switching cycles | |||||||
Rated current AC – cos j = 1.0 [A] / [n] | 30 / 10’000 | 25,0 / 10’000 | |||||
50 / 3’000 | 50,0 / 2’000 | ||||||
Rated current AC cos j = 0.6 [A] / [n] | — | 25 / 3’000 | |||||
Max. Switching current AC – cos j = 1.0 [A] / [n] | — | 75 / 3’000 | |||||
Rated voltage DC [V] | 12 | ||||||
Rated current DC [A] / [n] | — | 63 / 10’000 | |||||
Max. Switching current DC [A] / [n] | 60 / 10’000 | 100 / 3’000 | |||||
Other data | |||||||
High-voltage resistance [kV] | — | 2 | — | 2 | |||
Total bounce time [ms] | < 1 | ||||||
Contact resistance (according to MIL-Std. R 5757 ) [mΩ] | < 50 | ||||||
Impregnation resistance | suitable | ||||||
Pressure resistance of the switch housing [N] | 300 | 600 | |||||
Suitable for installation for protection class | I | I | I + II | ||||
Available licences | |||||||
please specify | IEC, VDE, UL, CQC | IEC, ENEC, VDE, UL, CQC | |||||
Dimensions (standard) | |||||||
Diameter d [mm] | 11,0 | 11,5 | 17,1 | 17,6 | |||
Overall height h [mm] | from 6,0 | from 6,5 | from 5.9 | from 6.3 | |||
Length of the insulation cap l [mm] | — | 19 | — | 35 | |||
Standard stranded wire connection: | 1.0 mm² / AWG 18 | 1.75 mm² / AWG 14 | |||||
Hint
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.