With epoxy coating for supply transformers belt type M150-30S (M097-30N) B = 17000 gauss, f = 50 Hz
Art. no. | D | d | H | Weight | Core cross- cutSn(*) |
Magnetic Iron way Lm |
Number of windings per volt |
Strom- dichte |
abgegebene Leistung |
[mm] | [mm] | [mm] | [kg] | [cm2] | [cm] | [A/mm2] | [W] | ||
RK035/022/015 | 35 | 22 | 15 | 0,063 | 0,97 | 8,95 | 28,8 | 5 | 7 |
RK050/030/020 | 50 | 30 | 20 | 0,182 | 2 | 12,56 | 13,94 | 4 | 20 |
RK063/038/020 | 63 | 38 | 20 | 0,290 | 2,5 | 15,85 | 11,18 | 3,8 | 32 |
RK063/038/025 | 63 | 38 | 25 | 0,360 | 3,12 | 15,85 | 8,95 | 3,4 | 40 |
RK070/040/020 | 70 | 40 | 20 | 0,380 | 3 | 17,27 | 9,29 | 3,6 | 50 |
RK070/040/025 | 70 | 40 | 25 | 0,474 | 3,75 | 17,27 | 7,44 | 3,4 | 62 |
RK070/040/032 | 70 | 40 | 32 | 0,606 | 4,8 | 17,27 | 5,8 | 3 | 80 |
RK080/050/025 | 80 | 50 | 25 | 0,560 | 3,75 | 20,41 | 7,44 | 3,2 | 100 |
RK080/050/032 | 80 | 50 | 32 | 0,716 | 4,8 | 20,41 | 5,8 | 3 | 120 |
RK080/050/040 | 80 | 50 | 40 | 0,896 | 6 | 20,41 | 4,64 | 2,8 | 180 |
RK100/050/032 | 100 | 50 | 32 | 1,377 | 8 | 23,55 | 3,48 | 2,6 | 220 |
RK100/050/040 | 100 | 50 | 40 | 1,722 | 10 | 23,55 | 2,78 | 2,4 | 300 |
RK100/060/032 | 100 | 60 | 32 | 1,176 | 6,4 | 25,12 | 4,35 | 3 | 260 |
RK100/060/040 | 100 | 60 | 40 | 1,470 | 8 | 25,12 | 3,48 | 2,7 | 340 |
RK120/060/032 | 120 | 60 | 32 | 1,97 | 9,6 | 28,26 | 2,9 | 2,6 | 380 |
RK120/060/040 | 120 | 60 | 40 | 2,5 | 12 | 28,26 | 2,32 | 2,5 | 500 |
RK120/060/050 | 120 | 60 | 50 | 3,08 | 15 | 28,26 | 1,85 | 2,4 | 630 |
RK140/060/050 | 140 | 60 | 50 | 4,56 | 20 | 31,4 | 1,39 | 2,3 | 850 |
RK160/050/050 | 160 | 80 | 50 | 5,5 | 20 | 37,68 | 1,39 | 2,2 | 1000 |
(*) To calculate the net iron cross-section, convert with filling factor K = 0.95. |
Iron-nickel cores (Fe-Ni), Mumetal
We are also able to supply Fe-Ni alloy cores in strip thicknesses of 0.10 mm and 0.20 mm. The property of higher initial permeability makes Fe-Ni alloys particularly suitable for the construction of measuring transformers, differential transformers, magnetic amplifiers, filters and in many cases for shielding field leakage. The use of state-of-the-art instruments for continuous testing during production guarantees the required magnetic properties of these products.
Overview of sheet metal qualities
Material | Quality | Tape thickness [mm] |
Frequency [Hz] |
Permeabilität µ4 |
Induction B withHeff | |
0.02 [As/cm] T |
0.05 [As/cm] T |
|||||
MUMETAL Fe -Ni78-80% |
A – 03 | 0,2 | 50 | 30000 | 0,27 | 0,51 |
A – 06 | 0,2 | 50 | 40000 | 0,33 | 0,51 | |
MUMETAL Fe -Ni78-80% |
A – 01 | 0,1 | 50 | 60000 | 0,40 | 0,55 |