Data overview for preferred ring belt cores

0,00

Art.-Nr.

With epoxy coating for supply transformers belt type M150-30S (M097-30N) B = 17000 gauss, f = 50 Hz

Art. no. D d H Weight Core cross-
cutSn(*)
Magnetic
Iron way Lm
Number of
windings
per volt
Strom-
dichte
abgegebene
Leistung
[mm] [mm] [mm] [kg] [cm2] [cm] [A/mm2] [W]
RK035/022/015 35 22 15 0,063 0,97 8,95 28,8 5 7
RK050/030/020 50 30 20 0,182 2 12,56 13,94 4 20
RK063/038/020 63 38 20 0,290 2,5 15,85 11,18 3,8 32
RK063/038/025 63 38 25 0,360 3,12 15,85 8,95 3,4 40
RK070/040/020 70 40 20 0,380 3 17,27 9,29 3,6 50
RK070/040/025 70 40 25 0,474 3,75 17,27 7,44 3,4 62
RK070/040/032 70 40 32 0,606 4,8 17,27 5,8 3 80
RK080/050/025 80 50 25 0,560 3,75 20,41 7,44 3,2 100
RK080/050/032 80 50 32 0,716 4,8 20,41 5,8 3 120
RK080/050/040 80 50 40 0,896 6 20,41 4,64 2,8 180
RK100/050/032 100 50 32 1,377 8 23,55 3,48 2,6 220
RK100/050/040 100 50 40 1,722 10 23,55 2,78 2,4 300
RK100/060/032 100 60 32 1,176 6,4 25,12 4,35 3 260
RK100/060/040 100 60 40 1,470 8 25,12 3,48 2,7 340
RK120/060/032 120 60 32 1,97 9,6 28,26 2,9 2,6 380
RK120/060/040 120 60 40 2,5 12 28,26 2,32 2,5 500
RK120/060/050 120 60 50 3,08 15 28,26 1,85 2,4 630
RK140/060/050 140 60 50 4,56 20 31,4 1,39 2,3 850
RK160/050/050 160 80 50 5,5 20 37,68 1,39 2,2 1000
(*) To calculate the net iron cross-section, convert with filling factor K = 0.95.

 

Iron-nickel cores (Fe-Ni), Mumetal

We are also able to supply Fe-Ni alloy cores in strip thicknesses of 0.10 mm and 0.20 mm. The property of higher initial permeability makes Fe-Ni alloys particularly suitable for the construction of measuring transformers, differential transformers, magnetic amplifiers, filters and in many cases for shielding field leakage. The use of state-of-the-art instruments for continuous testing during production guarantees the required magnetic properties of these products.

Overview of sheet metal qualities
Material Quality Tape thickness
[mm]
Frequency
[Hz]
Permeabilität
µ4
Induction B withHeff
0.02 [As/cm]
T
0.05 [As/cm]
T
MUMETAL
Fe -Ni78-80%
A – 03 0,2 50 30000 0,27 0,51
A – 06 0,2 50 40000 0,33 0,51
MUMETAL
Fe -Ni78-80%
A – 01 0,1 50 60000 0,40 0,55