Construction of cable
Conductor:
Nickel-plated copper stranded wire or pure nickel
Insulation:
PTFE 5Y according to VDE 0207 Part 6 Glass fibre braid with impregnation
Marking:
Optionally with coloured marking thread
Technical data
Temperature range:
-50 °C to + 260 °C, briefly 300 °C
Nominal voltage:
600 volts
Test voltage:
3.4 kV
| Master number | Cross section [mm2] | Strand structure | max. strand Ø [mm] | Outer Ø [mm] | Cu number [kg/km] | Weight approx [kg/km] |
| SLTEGL0050 | 0,5 | 16 x 0,203 | 1 | 2 | 4,8 | 10 |
| SLTEGL0075 | 0,75 | 24 x 0,203 | 1,25 | 2,2 | 7,5 | 14 |
| SLTEGL0100 | 1 | 32 x 0,203 | 1,4 | 2,4 | 9,8 | 16 |
| SLTEGL0150 | 1,5 | 30 x 0,254 | 1,7 | 2,7 | 14,4 | 22 |
| SLTEGL0250 | 2,5 | 50 x 0,254 | 2,15 | 3,3 | 24,4 | 36 |
| SLTEGL0400 | 4 | 56 x 0,3 | 2,7 | 3,8 | 38 | 52 |
| SLTEGL0600 | 6 | 84 x 0,3 | 3,3 | 4,5 | 58 | 71 |
Part number:
Conductor: N = Cu nickel-plated – R = Pure nickel
Example:
SLTEGL0050N
SLTEGL0050 = Master number
N = Cu Nickel Plated
Note
Kapton®/Fibre Glass stranded wires offer very good dielectric strength even in damp environments