Kapton®/Teflon® insulating tube, non-shrinking class, H (180 °C)

0,00

Not a stock item

Wound Insulation Tubes for applications in temperature class H.

  • Inner diameter from 1.6 mm.
  • Wall thicknesses from 0.075
  • For applications in temperature class H up to180 °C.
  • The insulating pipes are also available with color coding for differentiation.
  • The material is UL

Wound Insulation Tubes are made of Kapton® and coated with FEP for use in the most demanding applications. It is used where high dielectric strength, mechanical strength and moisture resistance are required despite low wall thicknesses. It is suitable for applications with the harshest environmental conditions and operating temperatures of up to 200 °C. The structure with adhesive-free welding guarantees that only FEP and polyimide are contained in the product.

Art.-Nr.

Technical data

Properties: Kapton® FN

Electrical properties
Feature Thickness Kapton® HN [mm] 0,0127 0,0254 0,0508 0,0508
Thickness FEP 0,0127 0,0127 0,0127 0,0254
Dielectric strength
Total [V] 6’300 4’000 11’400
[V/mil] 4’000 4’200 3’800
Dielectric constant 3,0 —- 3,1
Loss factor 0,0014 0,0011
Contact resistance
25°C [Ω-cm] 1017 1018 7 x 1017 8 x 1017
200°C [Ω-cm] 1014 9 x 1013

 

Physical properties
Property Thickness Kapton® FN Thickness FEP [mm] 0,0127 0,0254 0,0508 0,0508
0,0127 0,0127 0,0127 0,0254
Tear strength (LR)
25°C

200°C

[psi] 15’000 17’000 25’000 17’000
10’000 11’000 16’000 11’000
Tension for 3% elongation (LR)
25°C

200°C

[psi] 6’000 7’300 10’000 7’300
5’000 4’000 8’000 4’000
Tension for 5% elongation (LR)
25°C

200°C

[psi] 9’000 9’000
5’500 5’500
Tear elongation (LR)
25°C

200°C

[%] 50 75 80 >80
85
Train module (LR)
25°C

200°C

[psi] 320’000 320’000
173’000 173’000
Impact resistance at 25°C
[kg/cm] 7 14
[kg/mil] 4,6 4,6
Tear resistance (Elmendorf)
[g] 20
[g/mil] 7 13,5 12
Tear resistance (Graves)
[g] 650
[g/mil] 435
Polymide weight [%] 40 57 73 57
Weight FEP [%] 60 43 27 43
Density [g/cm3] 1,79 1,67 1,57 1,67

Chemical properties
Property Thickness Kapton® FN Thickness FEP [mm] 0,0254 0,0508 0,0508
0,0127 0,0127 0,0254
Moisture absorption at 25°C
(25°C) 50% Relative humidity [%] 0,8 0,8 0,8
98% Relative humidity [%] 1,7 1,7 1,7
Water vapor permeability g/(100 in.2 ) (24 h. 0,57
g/(100 in.2 ) (24 h)/mil 0,85

 

Item number:

IRNKFdddd/www/llll Example: IRNKF0100/005/0500 IRNKF = master number 0100 = 1.00 mm diameter 005 = 0.05 mm wall thickness 0500 = 500 mm length