CR6 |
SR6 |
Switch type: | NC contact CR6 self-retaining | NC contact SR6 latching | ||
isolated: | no | yes | ||
Temperature | ||||
Nominal switching temperature (NST), in 5 K steps | [°C] | 60 – 180 | ||
Tolerance range ≤ 140 °C | Tol [ [K] | ± 5 | ||
Tolerance range ≥140 °C | Tol [ [K] | ± 10 | ||
Switch-back temperature (RST below NST) | UL | [ [K] | ≥ 35 | |
(defined RST on customer request) | VDE | [ °C] | ≥ 35 | |
Tension | ||||
Operating voltage range up to … | 250 V | |||
Rated voltage AC | [VAC] | 120/230 (VDE), 250 (UL) | ||
Current/switching cycles | ||||
Rated current – cos j = 1.0 | [A] / [n] | 10,0 / 1’000 | ||
Rated current – cos j = 0.6 | [A] / [n] | 6,3 / 1’000 | ||
max. switching current– cos j = 1.0 | [A] / [n] | 25,0 / 1’000 | ||
Other data | ||||
High-voltage resistance | [kV] | — | 2 | |
Total bounce time | [ms] | < 1 | ||
Contact resistance (according to MIL-STD R5757) | [mΩ] | £ 50 | ||
Vibration resistance 10 … 60 Hz | [m/s2] | 100 | ||
Compressive strength of the switch housing | [N] | 600 | ||
Available licenses | ||||
please specify | IEC, ENEC, VDE, UL, CSA, CQC | |||
Dimensions (standard) | ||||
Diameter | Ø d [mm] | 9,0 | 9,4 | |
Overall height | h [mm] | from 6.3 | from 6.7 | |
Length of the insulation cap | l [mm] | — | 17,0 | |
Standard connection | Stranded wire: | 0.75 mm2/AWG 18 | ||
Functional diagram | ||||
The ceramic resistor connected in parallel to the switch heats up after the contact opens, which keeps the contact in the open state. |
Note
The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability for a specific application must be checked by the user in each individual case. We will of course be happy to advise you.