Thermal Protetors type P08 / H08 / V08; 4.0 – 25 A

0,00

 

C08, S08 and L08 are switches with surface-mounted enclosures, fully insulated, automatically resetting with Expoxy

 

P08 is with connection pins

 

S08 and L08 are equipped with connection cables.

 

Art.-Nr.
P08
H08
V08

 

 

Switching type Normally open contact P08 resetting Normally open contact H08 resetting Normally open contact V08 resetting
isolated: yes Yes yes
Temperature
Nominal switching temperature (NST), [°C]
in 5 K steps
70 – 200 70 – 150
Tolerance range -Standard Tol [K] ± 5
Reverse Switch Temperature (RST below NST)  UL [K]
Reverse Switch Temperature (RST below NST)  VDE [°C]
-35 ± 15
≥ 35
Tension
max. Operating voltage range AC to [VAC] 500 V
Rated voltage AC [VAC] 250 (VDE), 277 (UL)
Current/switching cycles
Rated current AC – cos φ = 1.0 [A] / [n] 10,0 / 10’000
Rated current AC – cos φ = 0.6 [A] / [n] 6,3 / 10’000
Additional specifications
High-voltage strength [kV] 2 3,75
Total bounce time ms] < 1
Contact resistance (according to MIL-STD R5757) [mΩ] < 50
Vibration resistance 10 … 60 Hz [m/s2] 100
Compressive strength of the switch housing [N] 600
Suitable for installation in protection class I + II I + II II + II
Impregnation resistance suitable
Available Licenses and Approvals
Please specify IEC, ENEC, VDE (appr. <150°C), CQC
Dimensions (standard)
Diameter or dimension Ø d or l x b [mm] 17 x 11,0 17,0 x 11,0 26,0 x 13,5
Overall height h [mm] from 6.0 from 7.5 from 10
Length of insulation cap l [mm]
Max. Torque [SW/Nm] 3,0 2,5
Standard stranded wire connection: 0.75 mm2/AWG18 0.50 mm2/AWG 20

 

P08 H08 V08

 

Note

The data and information provided are based on tests and test series. They are intended as a guide, which is why there may be deviations for individual applications and uses. The suitability in a specific application must be checked by the user in each individual case.

We will be pleased to advise you.